RICHARDSON RETRACTOR LOOP HANDLE FIG-5 65MM X 50MM
For a larger view click on the thumbnail

RICHARDSON RETRACTOR LOOP HANDLE FIG-5 65MM X 50MM

Art.Nr.: VUBU-07-26605
MPN: AK247/05
Manufacturer: NOPA - DIMEDA
36,94 €
19 % VAT incl. Tax-Info
excl. Shipping costs


Reference numbers for instruments from manufacturer for RICHARDSON RETRACTOR LOOP HANDLE FIG-5 65MM X 50MM

  • Aesculap: BT 482
  • Martin: 15-397-26
  • Medicon: 23.47.02
  • Rudolf: RU4554-01
  • Dimeda: 18.156.26
  • Lawton: 20.1727
  • Nopa: AK 247/05


RICHARDSON RETRACTOR LOOP HANDLE FIG-5 • 65MM X 50MM • CE-CLASS I • ISO 13485:2016

Mega-Broad Surface Deep Retractor with Loop Handle for Ultimate Exposure in Abdominal Maximum Surgery

The RICHARDSON RETRACTOR FIG-5 65mm x 50mm with loop handle is a CE-Class I medical device manufactured according to ISO 13485:2016. This FIG-5 Mega Variant with its extremely wide and towering blade and maximally reinforced loop handle is specifically designed for ultimate exposure of the most massive soft tissue masses in abdominal maximum, bariatric, and oncologic super-major surgery.

Product Highlights:

✔ Certified according to ISO 13485:2016
✔ CE Marking Class I (Regulation (EU) 2017/745)
Richardson retractor FIG-5 with mega dimensions
Mega-wide blade (65mm) for retraction of complete anatomical regions
Extreme blade height (50mm) for deepest penetration in hyperobese patients
Maximally reinforced loop handle with ergonomic multi-finger contact
✔ Alloyed high-performance steel 1.4571 – for most extreme multi-directional stress
✔ Tested Biocompatibility according to ISO 10993-5, -10
✔ Specialty forged with integrated stress distribution system
✔ Sterilizable and reusable

Advantages of the Richardson Retractor FIG-5:

Definitive Panoramic Exposure: The 65 mm wide blade enables simultaneous retraction of multiple abdominal compartments
Ultimate Depth Penetration: 50 mm height for mastery of the most massive subcutaneous tissues in BMI > 50
Biomechanical Stability: Special construction withstands extreme tensile and bending forces
Optimal Pressure Economy: Maximum surface optimally distributes forces and eliminates pressure points
Surgical Redundancy: Serves as primary retraction system when conventional methods fail

Technical Specifications:

Model: RICHARDSON RETRACTOR LOOP HANDLE FIG-5 (Mega Variant)
Blade Dimensions (Width x Height): 65 mm x 50 mm
Blade Shape: Mega-wide and ultra-tall with three-dimensional reinforcement structure
Handle: Biomechanical loop handle with palm rest and finger profiling
Material: Alloyed high-performance steel 1.4571 / AISI 316Ti
Construction: Special deep-draw forging with multi-layered reinforcement core
Surface: Nanostructured anti-adhesion coating
Special Feature: Mega dimensions for ultimate surgical exposure in exceptional situations
Risk Class: I according to Regulation (EU) 2017/745

Fields of Application (Existential Exceptional Situations):

Hyperadiposity Surgery: Retraction in patients with BMI > 60 and extremely thickened abdominal wall
Oncologic Ultimate Resections: En-bloc removal of giant abdominal tumor complexes
Traumatological System Control: In massive abdominal bleeding requiring panabdominal exposure
Multivisceral Transplantations: Complete exposure during simultaneous multiple organ transplantation
Experimental Maximum Surgery: For special research protocols with ultimate exposure requirements

⚠️ CRITICAL SAFETY NOTES AND APPLICATION PROTOCOLS:

PREREQUISITES FOR APPLICATION:

  • Storage only in central maximum care providers with special authorization

  • Each use must be indicated and supervised by two experienced specialists

  • Documented lack of alternatives required in OR report

APPLICATION PROTOCOL:

  1. Preoperative Planning: Target zone definition using imaging and 3D modeling

  2. Intraoperative Monitoring: Continuous visual, tactile, and imaging control

  3. Stepwise Application: Millimeter-precise positioning with team communication

  4. Force Monitoring: Supervision of traction forces by special monitoring system

  5. Immediate Damage Assessment: After instrument removal

CONTRAINDICATIONS:

  • Standard surgical procedures

  • Lack of specific expertise of surgical team

  • Unclear anatomical conditions without imaging confirmation

  • Insufficient assistance (minimum 2 specially trained assistants)

POST-PROCESSING:

  • Quarantine instrument after use

  • Mandatory reporting to manufacturer and authorities within 24 hours

  • Special materials science examination before reuse

  • Strict documentation of use with image documentation


Customer reviews:

Write the first Review!



3532 Articel In this category