RICHARDSON RETRACTOR LOOP HANDLE FIG-4 52MM X 22MM
For a larger view click on the thumbnail

RICHARDSON RETRACTOR LOOP HANDLE FIG-4 52MM X 22MM

Art.Nr.: VUBU-07-26604
MPN: AK247/04
Manufacturer: NOPA - DIMEDA
34,63 €
19 % VAT incl. Tax-Info
excl. Shipping costs


Reference numbers for instruments from manufacturer for RICHARDSON RETRACTOR LOOP HANDLE FIG-4 52MM X 22MM

  • Aesculap: BT 478
  • Martin: 15-395-24
  • Medicon: 23.45.04
  • Rudolf: RU4552-14
  • Dimeda: 18.150.04
  • Nopa: AK 247/04


RICHARDSON RETRACTOR LOOP HANDLE FIG-4 • 52MM X 22MM • CE-CLASS I • ISO 13485:2016

Ultra-Broad Surface Retractor with Loop Handle for Panoramic Exposure in Abdominal Large-Area Surgery

The RICHARDSON RETRACTOR FIG-4 52mm x 22mm with loop handle is a CE-Class I medical device manufactured according to ISO 13485:2016. This FIG-4 Ultra-Broad Surface Variant with its extremely wide, yet shallow blade and reinforced loop handle is specifically designed for panoramic exposure of large abdominal surgical fields with simultaneous shallow, tissue-preserving retraction.

Product Highlights:

✔ Certified according to ISO 13485:2016
✔ CE Marking Class I (Regulation (EU) 2017/745)
Richardson retractor FIG-4 with ultra-broad surface design
Extremely wide blade (52mm) for maximum area retraction
Optimized height (22mm) for shallow, tissue-preserving depth effect
Reinforced loop handle for secure grip during large-area retraction
✔ High-strength Stainless Steel 1.4441 – rust-proof, biocompatible and optimized for lateral bending stress
✔ Tested Biocompatibility according to ISO 10993
✔ Solid one-piece forged with lateral reinforcement ribs
✔ Sterilizable and reusable

Advantages of the Richardson Retractor FIG-4:

Panoramic Exposure: The 52 mm wide blade enables retraction of extremely large abdominal areas in a single motion
Optimal Pressure Distribution: The maximum width with moderate height optimally distributes traction forces and minimizes tissue trauma
Shallow Depth Effect: Ideal for exposure of large, but relatively flat surgical fields (e.g., large laparotomy wounds)
Reduced Instrument Density: Can replace several narrower retractors and improves overview in the surgical field
Surgical Efficiency: Enables rapid exposure of large areas during complex abdominal procedures

Technical Specifications:

Model: RICHARDSON RETRACTOR LOOP HANDLE FIG-4
Blade Dimensions (Width x Height): 52 mm x 22 mm
Blade Shape: Ultra-wide with moderate height according to FIG-4 design, laterally reinforced
Handle: Reinforced loop handle with extended contact area for multiple fingers
Material: High-strength Stainless Steel 1.4441 / AISI 316L
Construction: High-performance forged with integrated side reinforcements against bending
Surface: High-quality matte with reduced reflection
Special Feature: Ultra-broad surface design for panoramic exposure in abdominal large-area surgery
Risk Class: I according to Regulation (EU) 2017/745

Fields of Application (Specialty Indications):

Large-Area Abdominal Surgery: During extensive laparotomies requiring retraction of long wound edges
Visceral Major Resections: Exposure during extensive bowel resections or multivisceral procedures
Bariatric Surgery (moderate obesity): Retraction of abdominal wall in patients with broad but not extremely deep subcutaneous tissue
Oncologic Area Resections: During removal of large but flat tumor areas
Reconstructive Abdominal Wall Surgery: Retraction during extensive abdominal wall reconstructions

Important Safety and Application Notes:

FOR EXPERIENCED SURGICAL PROFESSIONALS ONLY
Apply only under direct visual control and with assisting stabilization
Extreme caution during positioning – the extreme width requires precise, straight alignment
Special attention to lateral stability – avoid transverse forces and twisting
Even, broad-surface pressure – apply entire blade evenly to tissue
Controlled traction forces – consider the large leverage effect and apply in a dosed manner
Not suitable for deep, narrow approaches – specifically designed for wide, shallow exposure
Check for deformations before each use – especially control lateral bending
During reprocessing intensively clean the extremely large blade surface
Special storage – protect from lateral bending, store flat