Tall-Blade Retractor with Loop Handle for Maximum Soft Tissue Retraction in Abdominal Maximum Surgery
The RICHARDSON RETRACTOR FIG-3 44mm x 38mm with loop handle is a CE-Class I medical device manufactured according to ISO 13485:2016. This FIG-3 Tall-Blade Variant with its extremely increased and widened blade and reinforced loop handle is specifically designed for maximum retraction of massive soft tissue masses in abdominal maximum, bariatric, and visceral major surgery.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE Marking Class I (Regulation (EU) 2017/745)
✔ Richardson retractor FIG-3 with tall-blade design
✔ Maximally expanded blade (44mm x 38mm) for ultimate area and depth retraction
✔ Reinforced loop handle for secure grip under extreme traction forces
✔ High-strength Stainless Steel 1.4441 – rust-proof, biocompatible and optimized for high load
✔ Tested Biocompatibility according to ISO 10993
✔ Solid one-piece forged for exceptional stability
✔ Sterilizable and reusable
Advantages of the Richardson Retractor FIG-3:
• Maximum Area Retraction: The 44 mm wide blade enables control of extremely large soft tissue areas
• Ultimate Depth Effect: 38 mm blade height for effective work in deepest tissue layers in obese patients
• Extreme Stability: Reinforced loop handle and massive blade design for highest load capacity
• Optimal Pressure Distribution: The maximum contact surface optimally distributes traction forces and minimizes local tissue trauma
• Surgical Efficiency: Can replace several standard retractors and simplifies OR management during large approaches
Technical Specifications:
• Model: RICHARDSON RETRACTOR LOOP HANDLE FIG-3
• Blade Dimensions (Width x Height): 44 mm x 38 mm
• Blade Shape: Tall blade according to FIG-3 design with maximum contouring and reinforcement
• Handle: Highly reinforced loop handle for secure finger hook under maximum load
• Material: High-strength Stainless Steel 1.4441 / AISI 316L
• Construction: High-performance forged with integrated reinforcement
• Surface: High-quality matte with special glide coating
• Special Feature: Tall-blade design with reinforced loop handle for maximum soft tissue retraction in abdominal maximum surgery
• Risk Class: I according to Regulation (EU) 2017/745
Fields of Application (Specialty Indications):
• Bariatric Surgery: Retraction of the extremely thickened abdominal wall in morbid obesity
• Visceral Maximum Surgery: During liver transplantations, multivisceral resections, and complete gastrectomies
• Abdominal Revision Surgery: Retraction during extensive revision operations with massive scar tissue
• Oncologic Major Resections: Exposure during en-bloc resections of giant abdominal tumors
• Trauma Surgery (Polytrauma): During simultaneous exposure of multiple abdominal compartments
Important Safety and Application Notes:
• FOR HIGHLY EXPERIENCED SURGICAL PROFESSIONALS ONLY
• Apply only under optimal visibility conditions with sufficient assistance
• Extreme caution during positioning – the maximum blade size requires precise placement
• Controlled, dosed force application – the extreme leverage requires highest control
• Secure grip – fingers must be correctly positioned in reinforced loop handle for optimal force transmission
• Even pressure – consciously and evenly apply the maximum blade surface
• Atraumatic application despite size – pay particular attention to gentle retraction
• Check structural integrity before each use – exclude material fatigue
• During reprocessing intensively clean the maximum blade surface and loop handle
• Professional storage – protect from deformation or damage
Write the first Review!