Ultimate Long Retractor for Complete Panoramic Deep Exposure in Ophthalmic Surgery
The DESMARRES Lid Retractor 16 mm / 16.0 cm is a Class I medical device manufactured according to ISO 13485:2016. This ultimate long retractor enables complete and controlled exposure of the entire periocular and orbital area during the most demanding ophthalmic maximum procedures in depth.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE marking Class I (Directive 93/42/EEC)
✔ Ultimate 16.0 cm long version for maximum depth reach
✔ Maximum 16 mm panoramic retraction blade for complete exposure
✔ Exclusively for most complex ophthalmic deep and maximum procedures
✔ High-quality stainless steel 1.4301 – rust-proof and biocompatible
✔ Tested biocompatibility according to ISO 10993
✔ Ultra-atraumatic, surgically polished precision tips
✔ Reinforced ergonomic professional long handle
✔ Sterilizable and reusable
Benefits of the Ultimate Long Retractor:
• Complete Deep Panoramic Exposure: 16.0 cm length with 16 mm width for maximum overview of all orbital spaces
• Optimal Stability with Maximum Access: Maximum blade ensures secure hold even with most extensive approaches
• Precise Deep Manipulation of All Areas: Extended professional handle enables exact work in all orbital regions
• Atraumatic Maximum Surface Application: Optimally distributed pressure protects tissue during most comprehensive exposure
• Indispensable Specialized Instrument: Essential for maximally extended orbital oncological, traumatological, and reconstructive procedures
Technical Specifications:
• Model: DESMARRES Lid Retractor, ultimate long version
• Blade Width: 16 mm (flat anatomically curved)
• Length: 16.0 cm (overall length)
• Curvature: Flat, anatomically precisely optimized
• Material: Surgical Stainless Steel 1.4301
• Tip Design: Ultra-atraumatically surgically polished
• Handle Design: Reinforced ergonomic professional long handle
• Risk Class: I according to Directive 93/42/EEC
Fields of Application:
• Maximum extended oncological orbital reconstructions
• Complete orbital decompressions in most severe diseases
• Extensive orbital trauma reconstructions with multiple approaches
• Deep orbital reconstructions after extensive inflammation
• Combined oculoplastic reconstructions with simultaneous deep access
Important Safety Instructions:
• FOR HIGHLY SPECIALIZED OPHTHALMIC PROFESSIONALS ONLY
• For lid retraction only – not for application on the globe
• Extreme caution when navigating in deep orbital spaces with critical structures
• Inspect for structural integrity and perfect condition before use
• Apply only under microscopic control and with extremely measured pressure
• For reuse, strictly adhere to reprocessing guidelines
Write the first Review!