DESMARRES RETRACTOR 8MM 13,0CM
For a larger view click on the thumbnail

DESMARRES RETRACTOR 8MM 13,0CM

Art.Nr.: VUBU-07-10908
MPN: AK090/08
Manufacturer: NOPA - DIMEDA
18,36 €
19 % VAT incl. Tax-Info
excl. Shipping costs


Reference numbers for instruments from manufacturer for DESMARRES RETRACTOR 8MM 13,0CM

  • Aesculap: OA 310
  • Martin: 34-271-13
  • Rudolf: RU9106-13
  • Dimeda: 18.230.08
  • Nopa: AK 090/08


DESMARRES LID RETRACTOR • 8MM • 13.0 CM • CE CLASS I • ISO 13485:2016

Precision Lid Retractor for Atraumatic Exposure in Ophthalmic Surgery

The DESMARRES Lid Retractor 8 mm / 13.0 cm is a Class I medical device manufactured according to ISO 13485:2016. This flat-curved precision retractor enables gentle and controlled retraction of the eyelids during ophthalmic procedures on the anterior and posterior segments of the eye.

Product Highlights:

✔ Certified according to ISO 13485:2016
✔ CE marking Class I (Directive 93/42/EEC)
✔ Flat-curved 8 mm retraction blade for optimal lid control
✔ Exclusively for ophthalmic surgical and periocular procedures
✔ High-quality stainless steel 1.4301 – rust-proof and biocompatible
✔ Tested biocompatibility according to ISO 10993
✔ Atraumatic, rounded tips
✔ Ergonomic handle for microsurgical precision
✔ Sterilizable and reusable

Benefits of the Precision Retractor:

• Optimal Lid Retraction: Flat, curved design for secure hold without globe pressure
• Maximum Exposure: Provides free access to conjunctiva, fornix, and anterior segment
• Atraumatic Application: Gentle tissue handling without lid trauma
• Precise Handling: Lightweight, balanced instrument for steady control
• Ophthalmic Standard: Proven instrument for lid surgery and bulbus access

Technical Specifications:

• Model: DESMARRES Lid Retractor
• Blade Width: 8 mm (flat curved)
• Length: 13.0 cm (overall length)
• Curvature: Flat, slightly S-shaped
• Material: Surgical Stainless Steel 1.4301
• Tip Design: Atraumatically rounded
• Handle Design: Ergonomic for microsurgical control
• Risk Class: I according to Directive 93/42/EEC

Fields of Application:

• Cataract Surgery (Phacoemulsification)
• Glaucoma Surgery (Trabeculectomy)
• Eyelid Corrections (Blepharoplasty)
• Lacrimal Surgery (Dacryocystorhinostomy)
• Oculoplastic Procedures and Tumor Excision

Important Safety Instructions:
• FOR OPHTHALMIC PROFESSIONALS ONLY
• For lid retraction only – not for application on the globe
• Inspect for deformations or damage before use
• Apply under microscopic visualization
• For reuse, strictly adhere to reprocessing guidelines


Customer reviews:

Write the first Review!



3532 Articel In this category