Flexible Maximum Vessel Dilator for Large-Caliber Vascular Surgery
The GARRETT VESSEL DILATOR FLEXIBLE 3.0MM 14.0 cm is a medical device of CE Class I according to ISO 13485:2016. This flexible maximum vessel dilator was specifically developed for the gentle dilation of large-caliber vessels in vascular surgery, cardiac surgery and trauma surgery.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE Marking Class I (Regulation (EU) 2017/745 MDR)
✔ Garrett Vessel Dilator with 3.0 mm maximum diameter
✔ Flexible version for anatomical adaptation
✔ High-quality Stainless Steel 1.4301 – rust-free and biocompatible
✔ Tested Biocompatibility according to ISO 10993
✔ Maximum 3.0 mm tip for large-caliber vessels
✔ Optimal 14.0 cm length for deep vascular surgical procedures
✔ Sterilizable and reusable
✔ Maximum dilator for most demanding vascular reconstructions
Benefits of the Garrett Vessel Dilator:
• Controlled Flexibility: Bendable yet maximum stability for secure vessel dilation
• Maximum Size: 3.0 mm ideal for large-caliber vessels and major anastomoses
• Atraumatic Maximum Tip: High-gloss polished surface minimizes vessel injuries
• Optimized Depth Reach: Proven length for excellent control in deep procedures
• Robust Maximum Design: High-quality instrument for most demanding vascular procedures
Technical Specifications:
• Model: GARRETT VESSEL DILATOR FLEXIBLE
• Total Length: 14.0 cm
• Diameter: 3.0 mm
• Construction: Flexible maximum vessel dilator
• Tip: Rounded, atraumatic
• Material: Stainless Steel 1.4301
• Form: Straight, controlled flexible shaft
• Surface: High-gloss polished for optimal gliding properties
• Flexibility: Low bend for maximum dilation stability
• Risk Class: I according to Regulation (EU) 2017/745 MDR
Fields of Application:
• Large-caliber vascular anastomoses in cardiac surgery
• Trauma major vascular reconstructions
• Peripheral bypass surgery with large-caliber vessels
• Arterial reconstructions of larger calibers
• Aorto-ilio-femoral vessel procedures
• Shunt surgery for dialysis patients with large vessels
• Vascular trauma care with major vessel involvement
Important Safety Information:
• FOR USE BY HIGHLY SPECIALIZED VASCULAR SURGICAL PROFESSIONALS ONLY
• Apply only under strict aseptic conditions
• Check for damage and surface integrity before use
• Use particularly controlled handling due to maximum caliber
• Extreme caution during dilation of large-caliber vessels
• Use very slow, guided dilation technique
• Stop dilation immediately if resistance is encountered
• Maximum care near major vascular structures
• Regular inspection of dilator tip
• Strictly follow reprocessing guidelines for reuse
Write the first Review!