Flexible Maximum Vessel Dilator for Most Demanding Vascular Surgery
The GARRETT VESSEL DILATOR FLEXIBLE 5.0MM 14.0 cm is a medical device of CE Class I according to ISO 13485:2016. This flexible maximum vessel dilator was specifically developed for the gentle dilation of largest vessels in vascular surgery, cardiac surgery and transplantation surgery.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE Marking Class I (Regulation (EU) 2017/745 MDR)
✔ Garrett Vessel Dilator with 5.0 mm maximum diameter
✔ Flexible version for anatomical adaptation
✔ High-quality Stainless Steel 1.4301 – rust-free and biocompatible
✔ Tested Biocompatibility according to ISO 10993
✔ Maximum 5.0 mm tip for largest vessels
✔ Optimal 14.0 cm length for deepest vascular surgical procedures
✔ Sterilizable and reusable
✔ Special instrument for most demanding maximum vessel reconstructions
Benefits of the Garrett Vessel Dilator:
• Maximum Flexibility: Bendable 5.0 mm version for largest vessel dilation
• For Maximum Vessels: Ideal for ascending/descending aorta, vena cava and main iliac trunks
• Atraumatic Maximum Tip: High-gloss polished surface minimizes vessel injuries
• Precise Handling: Optimal length for safe control in largest vessels
• Ultimate Robust Design: High-quality instrument for most demanding maximum vessel procedures
Technical Specifications:
• Model: GARRETT VESSEL DILATOR FLEXIBLE
• Total Length: 14.0 cm
• Diameter: 5.0 mm
• Construction: Flexible maximum vessel dilator
• Tip: Rounded, atraumatic
• Material: Stainless Steel 1.4301
• Form: Straight, flexible shaft
• Surface: High-gloss polished for optimal gliding properties
• Flexibility: Minimal bend for stable maximum vessel dilation
• Risk Class: I according to Regulation (EU) 2017/745 MDR
Fields of Application:
• Maximum vessel surgery (ascending/descending aorta)
• Main iliac trunk procedures
• Cardiac surgical major vessel reconstructions
• Transplantation surgery with maximum vessels
• Trauma maximum vessel repairs
• Complex bypass surgery
• Arterial maximum reconstructions
Important Safety Information:
• FOR USE BY HIGHLY SPECIALIZED VASCULAR SURGICAL PROFESSIONALS ONLY
• Apply only under strict aseptic conditions
• Check for damage and surface integrity before use
• Exercise extreme caution during dilation of largest, often atheromatous vessels
• Not suitable for excessive force application
• Use maximum controlled dilation technique
• Stop dilation immediately if resistance, calcification or plaques are encountered
• Exercise particular care near aneurysmal or dissected vascular structures
• Regular inspection of shaft stability and tip integrity required
• Strictly follow reprocessing guidelines for reuse