Flexible Large-Caliber Vessel Dilator for Deep Vascular Surgery
The GARRETT VESSEL DILATOR FLEXIBLE 2.5MM 21.0 cm is a medical device of CE Class I according to ISO 13485:2016. This flexible large-caliber vessel dilator with extended length was specifically developed for the gentle dilation of larger vessels in deep vascular surgery, cardiac surgery and transplantation surgery procedures.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE Marking Class I (Regulation (EU) 2017/745 MDR)
✔ Garrett Vessel Dilator with 2.5 mm diameter
✔ Flexible version for deep anatomical adaptation
✔ High-quality Stainless Steel 1.4301 – rust-free and biocompatible
✔ Tested Biocompatibility according to ISO 10993
✔ Large-caliber 2.5 mm tip for larger vessels
✔ Extended 21.0 cm length for deepest vascular surgical procedures
✔ Sterilizable and reusable
✔ Special instrument for demanding deep large-vessel reconstructions
Benefits of the Garrett Vessel Dilator:
• Flexible Large-Caliber Construction: Bendable 2.5 mm version for larger vessel dilation in depth
• For Deep Larger Vessels: Ideal for deep arteries and veins of medium caliber
• Atraumatic Large Tip: Smooth polished surface minimizes vessel injuries
• Controlled Deep Handling: Extended length for safe control in larger vessels in depth
• Robust Deep Special Design: Reliable instrument for demanding deep large-vessel procedures
Technical Specifications:
• Model: GARRETT VESSEL DILATOR FLEXIBLE
• Total Length: 21.0 cm
• Diameter: 2.5 mm
• Construction: Flexible large-caliber vessel dilator with deep reach
• Tip: Rounded, atraumatic
• Material: Stainless Steel 1.4301
• Form: Straight, flexible shaft
• Surface: High-gloss polished for optimal gliding properties
• Flexibility: Minimal bend for stable large-vessel dilation in depth
• Risk Class: I according to Regulation (EU) 2017/745 MDR
Fields of Application:
• Deep vascular surgical procedures on larger vessels
• Deep iliac vessel procedures
• Cardiac surgical deep vessel reconstructions
• Transplantation surgery with extended reach
• Trauma deep large vessel repairs
• Deep bypass surgery with larger vessels
• Arterial deep reconstructions in PAD
Important Safety Information:
• FOR USE BY EXPERIENCED VASCULAR SURGICAL PROFESSIONALS ONLY
• Apply only under strict aseptic conditions
• Check for damage and surface integrity before use
• Exercise particular caution during dilation of larger, often calcified vessels in depth
• Not suitable for excessive force application
• Use extremely controlled deep dilation technique
• Stop dilation immediately if resistance or calcification is encountered
• Exercise particular care near deep aneurysmal vascular structures
• Regular inspection of shaft stability with extended length required
• Exercise maximum attention with extended reach applications
• Strictly follow reprocessing guidelines for reuse
Write the first Review!