GARRETT VASCULAR DILATATOR MALLEABLE 4,5MM 14,0CM
For a larger view click on the thumbnail

GARRETT VASCULAR DILATATOR MALLEABLE 4,5MM 14,0CM

Art.Nr.: VUBU-08-20945
MPN: AL190/45
Manufacturer: NOPA - DIMEDA
21,26 €
19 % VAT incl. Tax-Info
excl. Shipping costs


Reference numbers for instruments from manufacturer for GARRETT VASCULAR DILATATOR MALLEABLE 4,5MM 14,0CM

  • Zepf: 56-4708-45
  • Codman: 25-8043
  • Nopa: AL 190/45


GARRETT VESSEL DILATOR FLEXIBLE 4.5MM • 14.0 CM • CE CLASS I • ISO 13485:2016

Flexible Large-Caliber Vessel Dilator for Demanding Vascular Surgery

The GARRETT VESSEL DILATOR FLEXIBLE 4.5MM 14.0 cm is a medical device of CE Class I according to ISO 13485:2016. This flexible large-caliber vessel dilator was specifically developed for the gentle dilation of large-caliber vessels in vascular surgery, cardiac surgery and transplantation surgery.

Product Highlights:

✔ Certified according to ISO 13485:2016
✔ CE Marking Class I (Regulation (EU) 2017/745 MDR)
✔ Garrett Vessel Dilator with 4.5 mm large-caliber
✔ Flexible version for anatomical adaptation
✔ High-quality Stainless Steel 1.4301 – rust-free and biocompatible
✔ Tested Biocompatibility according to ISO 10993
✔ Large-caliber 4.5 mm tip for major vessels
✔ Optimal 14.0 cm length for deep vascular surgical procedures
✔ Sterilizable and reusable
✔ Special instrument for demanding large-vessel reconstructions

Benefits of the Garrett Vessel Dilator:

Large-Caliber Flexibility: Bendable 4.5 mm version for major vessel dilation
For Major Vessels: Ideal for aorta, vena cava, iliac vessels and major arteries
Atraumatic Large Tip: Smooth polished surface minimizes vessel injuries
Controlled Handling: Optimal length for safe control in large vessels
Robust Special Design: Reliable instrument for demanding large-vessel procedures

Technical Specifications:

Model: GARRETT VESSEL DILATOR FLEXIBLE
Total Length: 14.0 cm
Diameter: 4.5 mm
Construction: Flexible large-caliber vessel dilator
Tip: Rounded, atraumatic
Material: Stainless Steel 1.4301
Form: Straight, flexible shaft
Surface: High-gloss polished for optimal gliding properties
Flexibility: Minimal bend for stable large-vessel dilation
Risk Class: I according to Regulation (EU) 2017/745 MDR

Fields of Application:

• Major vessel surgery (aorta, vena cava)
• Iliac vessel procedures
• Cardiac surgical vessel reconstructions
• Transplantation surgery
• Trauma major vessel repairs
• Bypass surgery with large vessels
• Arterial reconstructions in PAD

Important Safety Information:

• FOR USE BY EXPERIENCED VASCULAR SURGICAL PROFESSIONALS ONLY
• Apply only under strict aseptic conditions
• Check for damage and surface integrity before use
• Exercise particular caution during dilation of large, often calcified vessels
• Not suitable for excessive force application
• Use extremely controlled dilation technique
• Stop dilation immediately if resistance or calcification is encountered
• Exercise particular care near aneurysmal vascular structures
• Regular inspection of shaft stability required
• Strictly follow reprocessing guidelines for reuse