Flexible Mega Vessel Dilator for Deepest Major Vessel Procedures
The GARRETT VESSEL DILATOR FLEXIBLE 4.0MM 21.0 cm is a medical device of CE Class I according to ISO 13485:2016. This flexible mega vessel dilator with maximum length was specifically developed for the gentle dilation of largest main vessels in deepest vascular surgery, cardiac surgery and transplantation surgery maximum procedures.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE Marking Class I (Regulation (EU) 2017/745 MDR)
✔ Garrett Vessel Dilator with 4.0 mm mega diameter
✔ Flexible version for deepest anatomical adaptation
✔ High-quality Stainless Steel 1.4301 – rust-free and biocompatible
✔ Tested Biocompatibility according to ISO 10993
✔ Mega size 4.0 mm tip for largest main vessels
✔ Maximum 21.0 cm length for deepest maximum procedures
✔ Sterilizable and reusable
✔ Mega special instrument for most demanding deep main vessel reconstructions
Benefits of the Garrett Vessel Dilator:
• Mega Flexibility in Depth: Bendable 4.0 mm version for largest vessel dilation in deepest body regions
• For Deepest Main Vessels: Ideal for deep aorta, vena cava and main iliac trunks with maximum diameter
• Atraumatic Mega Tip: High-gloss polished surface minimizes vessel injuries in mega caliber
• Precise Mega Deep Handling: Maximum length for safe control in largest main vessels in depth
• Ultimate Mega Design: Highest quality instrument for most demanding deep mega vessel procedures
Technical Specifications:
• Model: GARRETT VESSEL DILATOR FLEXIBLE
• Total Length: 21.0 cm
• Diameter: 4.0 mm
• Construction: Flexible mega vessel dilator with deep reach
• Tip: Rounded, atraumatic
• Material: Stainless Steel 1.4301
• Form: Straight, flexible shaft
• Surface: High-gloss polished for optimal gliding properties
• Flexibility: Minimal bend for stable mega vessel dilation in depth
• Risk Class: I according to Regulation (EU) 2017/745 MDR
Fields of Application:
• Deepest main vessel surgery (aorta, vena cava)
• Deep iliac mega vessel procedures
• Cardiac surgical deep maximum reconstructions
• Transplantation surgery with mega vessels and ultra reach
• Trauma deep mega vessel repairs
• Most complex deep bypass surgery with main vessels
• Arterial deep mega reconstructions
Important Safety Information:
• FOR USE BY MEGA-SPECIALIZED VASCULAR SURGICAL PROFESSIONALS ONLY
• Apply only under strict aseptic conditions in maximum care centers
• Check for damage and surface integrity before use
• Exercise extreme caution during dilation of largest main vessels with pathological alterations in depth
• Not suitable for excessive force application
• Use mega-controlled deep dilation technique
• Stop dilation immediately if resistance, massive calcifications or unstable plaques are encountered
• Exercise maximum care near deep aneurysmal, dissected or rupture-prone main vascular structures
• Intensive regular inspection of shaft stability and tip integrity with ultra reach required
• Exercise utmost concentration and attention with maximum reach applications
• Special caution in patients with end-stage vascular disease
• Strictly follow reprocessing guidelines for reuse
Write the first Review!