Straight Midfacial Retractor for Stable Soft Tissue Exposure
The OBWEGESER Retractor straight, 10x45mm, 24.0 cm is a Class I medical device according to ISO 13485:2016. This specialized straight retractor with its tall, narrow blade form is a standard instrument in oral and maxillofacial surgery (OMFS) as well as in plastic facial surgery. It was designed for precise and stable retraction of soft tissues in the midface, orbital, and nasal regions.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE marking Class I (Directive 93/42/EEC)
✔ Straight OBWEGESER design with tall, narrow blade
✔ Tall blade (10x45 mm) for deep and precise tissue retraction
✔ High-quality stainless steel 1.4401 – corrosion-resistant and biocompatible
✔ Biocompatibility tested according to ISO 10993
✔ Atraumatically rounded edges for maximum patient safety
✔ Optimal length of 24.0 cm for good leverage in midfacial approaches
✔ Sterilizable and reusable
Advantages of the Straight Retractor:
• Precise Deep Retraction: The tall, narrow blade enables reaching and retracting deep-seated structures in the midface and periorbital area
• Stable Exposure: Provides reliable holding of soft tissues during osteotomies, fracture treatments, and reconstructive procedures
• Versatile Application: Ideal for rhinoplasty, orbital surgery, zygomatic repositioning, and maxillary sinus access
• Minimal Visual Obstruction: The narrow design hardly blocks the surgical field
• Ergonomic Handling: The straight form allows direct force transmission and good control
Technical Specifications:
• Model: OBWEGESER RETRACTOR straight
• Total Length: 24.0 cm
• Blade Dimensions: 10 mm (width) x 45 mm (height)
• Construction: Straight, tall single-piece blade
• Tip: Atraumatically rounded
• Material: Stainless steel 1.4401
• Shape: Straight, tall blade with smooth transitions
• Handle: Ergonomic handgrip for secure guidance
• Surface: High-gloss polished for optimal glide properties
• Special Feature: Standard instrument for precise midfacial exposure
• Risk Class: I according to Directive 93/42/EEC
Fields of Application:
• Rhinoplasty (open and closed techniques)
• Orbital surgery and orbital floor reconstruction
• Treatment of zygomatic fractures
• Access to maxillary sinus (Caldwell-Luc)
• Reconstructive procedures in nasal and midfacial regions
• Removal of tumors in nasal cavity and ethmoid bone
Special Safety Notes:
• EXCLUSIVELY for experienced OMFS or plastic facial surgery personnel
• Careful handling required near the infraorbital nerve and lacrimal apparatus
• Before use, check for structural integrity and smoothness of edges
• Apply atraumatic technique to avoid soft tissue damage
• Do not use as a lever for bony structures
• Discard immediately if bent or damaged
• When reusing, strictly follow reprocessing guidelines
Write the first Review!