Ultimate Panoramic Retractor for Complete Exposure in Complex Ophthalmic Surgery
The DESMARRES Lid Retractor 18 mm / 13.0 cm is a Class I medical device manufactured according to ISO 13485:2016. This ultimate panoramic retractor enables complete and controlled exposure of the entire periocular area during the most demanding ophthalmic maximum procedures, reconstructions, and oncological surgeries.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE marking Class I (Directive 93/42/EEC)
✔ Ultimate 18 mm panoramic retraction surface for complete exposure
✔ Exclusively for most complex ophthalmic maximum procedures and oncological resections
✔ High-quality stainless steel 1.4301 – rust-proof and biocompatible
✔ Tested biocompatibility according to ISO 10993
✔ Ultra-atraumatic, surgically polished precision tips
✔ Reinforced ergonomic professional comfort handle
✔ Sterilizable and reusable
Benefits of the Ultimate Panoramic Retractor:
• Complete 180° Panoramic Exposure: 18 mm blade for maximum overview of the entire orbital and periocular surgical field
• Optimal Access Possibilities: Enables simultaneous access to multiple structures (lid, conjunctiva, fornix, orbit) in one visual field
• Maximum Tissue Preservation: Largest possible surface optimally distributes retraction pressure and minimizes tissue trauma
• Professional Handling in Long-term Procedures: Specifically designed for longest and most complex ophthalmic procedures
• Indispensable Specialist Instrument: Essential for extensive oncological resections, complete lid reconstructions, and orbital reconstruction procedures
Technical Specifications:
• Model: DESMARRES Lid Retractor, ultimate panoramic version
• Blade Width: 18 mm (flat anatomically curved)
• Length: 13.0 cm (overall length)
• Curvature: Flat, anatomically precisely optimized
• Material: Surgical Stainless Steel 1.4301
• Tip Design: Ultra-atraumatically surgically polished
• Handle Design: Reinforced professional comfort handle
• Risk Class: I according to Directive 93/42/EEC
Fields of Application:
• Complete oncological orbital reconstructions after extensive tumor excision
• Total lid reconstructions after extensive trauma or complete tumor resection
• Maximum extended orbital decompressions in severe endocrine orbitopathy
• Complex conjunctival and fornix reconstructions in severe chemical burns or thermal injuries
• Combined oculoplastic reconstruction procedures with simultaneous access to multiple areas
Important Safety Instructions:
• FOR HIGHLY SPECIALIZED OPHTHALMIC PROFESSIONALS ONLY
• For lid retraction only – not for application on the globe
• Special caution with fragile, atrophic, or scarred tissue conditions
• Inspect for structural integrity and perfect condition before use
• Apply only under microscopic control and with measured pressure
• For reuse, strictly adhere to reprocessing guidelines
Write the first Review!