Large-Caliber Vessel Dilator for Demanding Vascular Surgery
The COOLEY VESSEL DILATOR FLEXIBLE 2.0MM 13.0 cm is a medical device of CE Class I according to ISO 13485:2016. This flexible large-caliber dilator was specifically developed for the gentle dilation of medium to larger vessels in vascular surgery, plastic surgery and trauma surgery.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE Marking Class I (Regulation (EU) 2017/745 MDR)
✔ Cooley Vessel Dilator with 2.0 mm diameter
✔ Flexible version for demanding vessel dilation
✔ High-quality Stainless Steel 1.4301 – rust-free and biocompatible
✔ Tested Biocompatibility according to ISO 10993
✔ Large-caliber 2.0 mm tip for medium to larger vessels
✔ Optimal 13.0 cm length for vascular standard procedures
✔ Sterilizable and reusable
✔ Robust instrument for demanding vascular reconstructions
Benefits of the Cooley Vessel Dilator:
• Stable Flexibility: Bendable yet stable construction for controlled vessel dilation
• Large-Caliber Size: 2.0 mm ideal for medium to larger vessels and bypass anastomoses
• Atraumatic Large Tip: Smooth polished surface minimizes vessel injuries
• Optimized Handling: Proven length for safe control
• High-Quality Design: Robust instrument for demanding procedures
Technical Specifications:
• Model: COOLEY VESSEL DILATOR FLEXIBLE
• Total Length: 13.0 cm
• Diameter: 2.0 mm
• Construction: Flexible large-caliber vessel dilator
• Tip: Rounded, atraumatic
• Material: Stainless Steel 1.4301
• Form: Straight, flexible shaft
• Surface: High-gloss polished for optimal gliding properties
• Flexibility: Minimal bend for stable vessel dilation
• Risk Class: I according to Regulation (EU) 2017/745 MDR
Fields of Application:
• Vascular surgical standard anastomoses
• Plastic surgical reconstructions
• Trauma vascular repairs
• Bypass surgery
• Arterial and venous reconstructions
• Shunt surgery
• General medium-caliber vessel procedures
Important Safety Information:
• FOR USE BY SURGICAL PROFESSIONALS ONLY
• Apply only under strict aseptic conditions
• Check for damage and surface integrity before use
• Exercise particular caution during dilation of larger vessels
• Not suitable for excessive force application
• Use controlled dilation technique
• Stop dilation immediately if resistance is encountered
• Exercise particular care near larger vascular structures
• Regular inspection of shaft stability required
• Strictly follow reprocessing guidelines for reuse
Write the first Review!