Mega Vessel Dilator for Most Extreme Major Vessel Surgery
The COOLEY VESSEL DILATOR FLEXIBLE 5.0MM 13.0 cm is a medical device of CE Class I according to ISO 13485:2016. This flexible mega dilator was specifically developed for the gentle dilation of extremely large main vessels in most extreme vascular surgery, cardiac surgery and transplantation surgery.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE Marking Class I (Regulation (EU) 2017/745 MDR)
✔ Cooley Vessel Dilator with 5.0 mm mega diameter
✔ Flexible version for most extreme vessel dilation
✔ High-quality Stainless Steel 1.4301 – rust-free and biocompatible
✔ Tested Biocompatibility according to ISO 10993
✔ Mega 5.0 mm tip for extremely large main vessels
✔ Optimal 13.0 cm length for precise mega vessel procedures
✔ Sterilizable and reusable
✔ Mega special instrument for most demanding main vessel reconstructions
Benefits of the Cooley Vessel Dilator:
• Mega Flexibility: Bendable yet ultra-stable construction for most precise vessel dilation
• Mega Size: 5.0 mm ideal for extremely large vessels, aorta, vena cava and main trunk anastomoses
• Atraumatic Mega Tip: High-gloss polished surface minimizes vessel injuries in mega caliber
• Precise Mega Handling: Optimal length for ultimate control in mega vessel procedures
• High-Quality Mega Design: Robust ultra-precision instrument for most demanding procedures
Technical Specifications:
• Model: COOLEY VESSEL DILATOR FLEXIBLE
• Total Length: 13.0 cm
• Diameter: 5.0 mm
• Construction: Flexible mega vessel dilator
• Tip: Rounded, ultra-atraumatic
• Material: Stainless Steel 1.4301
• Form: Straight, flexible mega shaft
• Surface: High-gloss polished for optimal gliding properties
• Flexibility: Minimal bend for stable mega vessel dilation
• Risk Class: I according to Regulation (EU) 2017/745 MDR
Fields of Application:
• Most extreme vascular surgical mega anastomoses
• Cardiac surgical mega vessel reconstructions
• Transplantation surgery with mega vessels
• Aortic surgery and iliac mega reconstructions
• Trauma mega vessel repairs
• Most complex bypass surgery with main trunks
• Arterial mega reconstructions
Important Safety Information:
• FOR USE BY MEGA-SPECIALIZED VASCULAR SURGICAL PROFESSIONALS ONLY
• Apply only under strict aseptic conditions in specialized centers
• Check for damage and surface integrity before use
• Exercise extreme caution during dilation of extremely large, often atheromatous or calcified vessels
• Not suitable for excessive force application
• Use ultra-controlled dilation technique
• Stop dilation immediately if resistance, massive calcifications or plaques are encountered
• Exercise maximum care near aneurysmal or dissected mega vascular structures
• Intensive regular inspection of shaft stability and tip integrity required
• Use only after comprehensive imaging diagnostics
• Special caution in patients with mega vessel pathologies
• Strictly follow reprocessing guidelines for reuse
Write the first Review!