Premium Large-Caliber Vessel Dilator for Demanding Vascular Surgery
The COOLEY VESSEL DILATOR FLEXIBLE 2.5MM 13.0 cm is a medical device of CE Class I according to ISO 13485:2016. This flexible premium large-caliber dilator was specifically developed for the gentle dilation of larger vessels in demanding vascular surgery, cardiac surgery and transplantation surgery.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE Marking Class I (Regulation (EU) 2017/745 MDR)
✔ Cooley Vessel Dilator with 2.5 mm premium diameter
✔ Flexible version for demanding vessel dilation
✔ High-quality Stainless Steel 1.4301 – rust-free and biocompatible
✔ Tested Biocompatibility according to ISO 10993
✔ Premium 2.5 mm tip for larger vessels and main branches
✔ Optimal 13.0 cm length for precise vascular surgical procedures
✔ Sterilizable and reusable
✔ Premium instrument for demanding large-vessel reconstructions
Benefits of the Cooley Vessel Dilator:
• Premium Flexibility: Bendable yet highly stable construction for precise vessel dilation
• Premium Size: 2.5 mm ideal for larger vessels, main arteries and bypass anastomoses
• Atraumatic Premium Tip: High-gloss polished surface minimizes vessel injuries
• Precise Handling: Optimal length for maximum control in large vessel procedures
• High-Quality Premium Design: Robust precision instrument for most demanding procedures
Technical Specifications:
• Model: COOLEY VESSEL DILATOR FLEXIBLE
• Total Length: 13.0 cm
• Diameter: 2.5 mm
• Construction: Flexible premium large-caliber vessel dilator
• Tip: Rounded, ultra-atraumatic
• Material: Stainless Steel 1.4301
• Form: Straight, flexible premium shaft
• Surface: High-gloss polished for optimal gliding properties
• Flexibility: Minimal bend for stable large-vessel dilation
• Risk Class: I according to Regulation (EU) 2017/745 MDR
Fields of Application:
• Demanding vascular surgical large anastomoses
• Plastic surgical premium reconstructions
• Cardiac surgical vessel reconstructions
• Transplantation surgery
• Trauma large vessel repairs
• Bypass surgery with larger vessels
• Arterial premium reconstructions
Important Safety Information:
• FOR USE BY EXPERIENCED VASCULAR SURGICAL PROFESSIONALS ONLY
• Apply only under strict aseptic conditions
• Check for damage and surface integrity before use
• Exercise particular caution during dilation of larger, often calcified vessels
• Not suitable for excessive force application
• Use highly controlled dilation technique
• Stop dilation immediately if resistance or calcification is encountered
• Exercise particular care near aneurysmal vascular structures
• Regular inspection of shaft stability and tip integrity required
• Strictly follow reprocessing guidelines for reuse
Write the first Review!