Extended Ultra-Wide Retractor for Maximum Deep Exposure in Ophthalmic Surgery
The DESMARRES Lid Retractor 14 mm / 16.0 cm is a Class I medical device manufactured according to ISO 13485:2016. This extended ultra-wide retractor enables comprehensive and controlled retraction of the eyelids during the most demanding ophthalmic deep procedures requiring maximum exposure of extensive orbital spaces.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE marking Class I (Directive 93/42/EEC)
✔ Extended 16.0 cm version for maximum depth reach
✔ Ultra-wide 14 mm retraction blade for optimal surface control
✔ Exclusively for most demanding ophthalmic deep and maximum procedures
✔ High-quality stainless steel 1.4301 – rust-proof and biocompatible
✔ Tested biocompatibility according to ISO 10993
✔ Ultra-atraumatic, surgically polished tips
✔ Reinforced ergonomic professional long handle
✔ Sterilizable and reusable
Benefits of the Extended Ultra-Wide Retractor:
• Maximum Depth and Surface Exposure: 16.0 cm length with 14 mm width for complete overview of extensive orbital areas
• Optimal Stability in Difficult Access: Ultra-wide blade ensures secure hold even with deep and narrow access angles
• Precise Manipulation in Depth: Extended professional handle enables exact work in all orbital quadrants
• Atraumatic Large-Surface Application in Depth: Optimal pressure distribution protects tissue even with maximum access
• Specialized Instrument for Complex Orbital Surgery: Essential for extensive orbital oncological and reconstructive procedures
Technical Specifications:
• Model: DESMARRES Lid Retractor, extended ultra-wide
• Blade Width: 14 mm (flat anatomically curved)
• Length: 16.0 cm (overall length)
• Curvature: Flat, anatomically precisely optimized
• Material: Surgical Stainless Steel 1.4301
• Tip Design: Ultra-atraumatically surgically polished
• Handle Design: Reinforced ergonomic professional long handle
• Risk Class: I according to Directive 93/42/EEC
Fields of Application:
• Extensive oncological orbital reconstructions after tumor excision
• Deep orbital decompressions in most severe endocrine orbitopathy
• Complex retrobulbar and intraorbital reconstructions
• Orbital reconstructions after extensive trauma with bone involvement
• Deep orbital inflammatory and fistula surgery with extensive access
Important Safety Instructions:
• FOR HIGHLY SPECIALIZED OPHTHALMIC PROFESSIONALS ONLY
• For lid retraction only – not for application on the globe
• Special caution when navigating in deep orbital spaces with neurovascular structures
• Inspect for structural integrity and perfect condition before use
• Apply under microscopic visualization and with measured pressure
• For reuse, strictly adhere to reprocessing guidelines
Write the first Review!