Extra-Wide Precision Lid Retractor for Ultimate Exposure in Ophthalmic Surgery
The DESMARRES Lid Retractor 14 mm / 13.0 cm is a Class I medical device manufactured according to ISO 13485:2016. This extra-wide precision retractor enables comprehensive and controlled retraction of the eyelids during the most demanding ophthalmic procedures requiring maximum exposure of the entire periocular area.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE marking Class I (Directive 93/42/EEC)
✔ Extra-wide 14 mm retraction blade for ultimate lid control
✔ Exclusively for most demanding ophthalmic surgical procedures
✔ High-quality stainless steel 1.4301 – rust-proof and biocompatible
✔ Tested biocompatibility according to ISO 10993
✔ Atraumatic, perfectly rounded tips
✔ Reinforced ergonomic comfort handle for maximum control
✔ Sterilizable and reusable
Benefits of the Extra-Wide Precision Retractor:
• Ultimate Lid Retraction: 14 mm blade for maximum exposure of the entire periocular surgical field
• Optimal Panoramic Overview: Provides free 180° access to extensive areas of conjunctiva, fornix, and orbit
• Atraumatic Super-Surface Application: Optimally distributed pressure over extra-large area spares even sensitive lid tissue
• Extremely Stable Premium Handling: Highly stable construction for secure retraction during most complex and lengthy procedures
• Ophthalmic Specialist Instrument: Premium instrument for most demanding lid, conjunctival, and orbital procedures
Technical Specifications:
• Model: DESMARRES Lid Retractor, extra-wide
• Blade Width: 14 mm (flat curved)
• Length: 13.0 cm (overall length)
• Curvature: Flat, anatomically optimized curve
• Material: Surgical Stainless Steel 1.4301
• Tip Design: Ultra-atraumatically rounded
• Handle Design: Reinforced comfort handle for maximum control
• Risk Class: I according to Directive 93/42/EEC
Fields of Application:
• Highly complex cataract surgery with combined procedures
• Extensive glaucoma revision surgery and drainage implants
• Large-scale oncological lid and orbital reconstructions
• Complex conjunctival and fornix reconstructions after trauma or burns
• Orbital decompressions and extensive orbital tumor excisions
Important Safety Instructions:
• FOR HIGHLY EXPERIENCED OPHTHALMIC PROFESSIONALS ONLY
• For lid retraction only – not for application on the globe
• Special caution with thin, atrophic, or scarred lid tissue
• Inspect for deformations or damage before use
• Apply under microscopic visualization
• For reuse, strictly adhere to reprocessing guidelines
Write the first Review!