PRATT Tenaculum Forcep 4x4 teeth 26 cm
For a larger view click on the thumbnail

PRATT Tenaculum Forcep 4x4 teeth 26 cm

Art.Nr.: VUBU-70-53826
MPN: 70.538.26
Manufacturer: NOPA - DIMEDA
52,72 €
19 % VAT incl. Tax-Info
excl. Shipping costs


Reference numbers for instruments from manufacturer for PRATT Tenaculum Forcep 4x4 teeth 26 cm

Dimeda: 70.538.26



PRATT UTERINE TENACULUM • 4X4 TEETH • 26 CM • CE CLASS I • ISO 13485:2016

Extended quadruple tooth uterine tenaculum for complex gynecological procedures

The PRATT Uterine Tenaculum with 4x4 teeth and a length of 26 cm is a CE Class I medical device according to ISO 13485:2016. This extended quadruple tooth tenaculum enables ultimate fixation security of the cervix uteri during complex gynecological procedures with difficult access conditions.

Product Highlights:

✔ Certified according to ISO 13485:2016
✔ CE Mark Class I (Directive 93/42/EEC)
✔ Extended quadruple tooth tenaculum with 26 cm length
✔ 4x4 teeth for maximum grip security
✔ High-quality stainless steel 1.4301 - rust-free and biocompatible
✔ Tested biocompatibility according to ISO 10993
✔ Precision-crafted sharp teeth
✔ Ergonomic ring handles
✔ Sterilizable and reusable

Advantages of the PRATT Quadruple Tenaculum 26 cm:

Extended length: 26 cm for optimal accessibility in obese patients
Quadruple teeth: 4x4 teeth for extreme hold under difficult conditions
Maximum grip security: Prevents slipping even during strong manipulations
Optimal pressure distribution: Multiple teeth minimize tissue trauma
Professional application: Specifically for complex surgical techniques

Technical Specifications:

• Model: PRATT Uterine Tenaculum
• Length: 26 cm
• Teeth: 4x4 sharp teeth (quadruple teeth configuration)
• Material: Surgical Steel 1.4301
• Handle design: Ergonomic ring handles
• Closure: Ratcheted
• Risk Class: I according to Directive 93/42/EEC

Special Features:

PRATT quadruple teeth: Proven 4x4 teeth configuration
Extended reach: 26 cm for procedures with difficult access
Maximum anchoring: Particularly suitable for resistant tissue

Areas of Application:

• Maximum fixation in obese patients
• Complex gynecological operations
• Hysteroscopies and endoscopic procedures
• Oncological gynecological techniques
• Reconstructive pelvic surgery

Important Safety Information:
• FOR USE BY EXPERIENCED GYNECOLOGICAL PROFESSIONALS ONLY
• Use only for corresponding clinical indications
• Special caution required due to quadruple teeth and extended length
• Check for damage and sharpness of teeth before each use
• Targeted application to minimize tissue traumatization
• Proceed with particular care in rigid tissue conditions
• Strictly follow reprocessing guidelines for reuse


Customer reviews:

Write the first Review!



3533 Articel In this category