Large-Caliber Vessel Dilator for Deep Vascular Surgery
The DE BAKEY VESSEL DILATOR FLEXIBLE 2.0MM 19.0 cm is a medical device of CE Class I according to ISO 13485:2016. This flexible large-caliber dilator with extended length was specifically developed for the gentle dilation of medium to larger vessels in deep vascular surgery, plastic surgery and trauma surgery procedures.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE Marking Class I (Regulation (EU) 2017/745 MDR)
✔ DeBakey Vessel Dilator with 2.0 mm diameter
✔ Flexible version for deep demanding vessel dilation
✔ High-quality Stainless Steel 1.4301 – rust-free and biocompatible
✔ Tested Biocompatibility according to ISO 10993
✔ Large-caliber 2.0 mm tip for medium to larger vessels
✔ Extended 19.0 cm length for deep vascular standard procedures
✔ Sterilizable and reusable
✔ Robust instrument for deep demanding vascular reconstructions
Benefits of the DeBakey Vessel Dilator:
• Stable Deep Flexibility: Bendable yet stable construction for controlled vessel dilation in depth
• Large-Caliber Size with Reach: 2.0 mm ideal for medium to larger vessels and deep bypass anastomoses
• Atraumatic Deep Large Tip: Smooth polished surface minimizes vessel injuries
• Optimized Deep Handling: Extended length for safe control in deep regions
• High-Quality Deep Design: Robust instrument for deep demanding procedures
Technical Specifications:
• Model: DE BAKEY VESSEL DILATOR FLEXIBLE
• Total Length: 19.0 cm
• Diameter: 2.0 mm
• Construction: Flexible large-caliber vessel dilator with deep reach
• Tip: Rounded, atraumatic
• Material: Stainless Steel 1.4301
• Form: Straight, flexible shaft
• Surface: High-gloss polished for optimal gliding properties
• Flexibility: Minimal bend for stable vessel dilation in depth
• Risk Class: I according to Regulation (EU) 2017/745 MDR
Fields of Application:
• Deep vascular surgical standard anastomoses
• Plastic surgical deep reconstructions
• Trauma deep vascular repairs
• Deep bypass surgery
• Arterial and venous deep reconstructions
• Deep shunt surgery
• General deep medium-caliber vessel procedures
Important Safety Information:
• FOR USE BY SURGICAL PROFESSIONALS ONLY
• Apply only under strict aseptic conditions
• Check for damage and surface integrity before use
• Exercise particular caution during dilation of larger vessels in depth
• Not suitable for excessive force application
• Use controlled deep dilation technique
• Stop dilation immediately if resistance is encountered
• Exercise particular care near larger deep vascular structures
• Regular inspection of shaft stability with extended length required
• Exercise increased attention with extended reach applications
• Strictly follow reprocessing guidelines for reuse
Write the first Review!