Precision Vessel Stripper for Minimal Invasiveness
The VESSEL STRIPPER 2.0 mm / 50.0 cm is a medical device of CE Class I according to ISO 13485:2016. This precision stripper with its minimal 2.0 mm tip and extra-long construction is specifically designed for the atraumatic removal of vein segments in minimally invasive vascular surgery.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE marking Class I (Regulation (EU) 2017/745 MDR)
✔ Extra long 50.0 cm construction for deep access
✔ Precision design with minimal 2.0 mm atraumatic tip
✔ High-quality stainless steel 1.4301 – rust-free and biocompatible
✔ Tested biocompatibility according to ISO 10993
✔ Atraumatic olive for safe tissue handling
✔ Maximum 50.0 cm length for deepest surgical access
✔ Sterilizable and reusable
Advantages of the Vessel Stripper:
• Minimally Invasive Tip: 2.0 mm design for smallest access pathways
• Extra Length: 50.0 cm for deepest vein segments and complex anatomies
• Atraumatic Olive: Gentle vein preparation without tissue trauma
• Precise Handling: Optimized balance for controlled stripping movements
• Complete Vein Removal: Enables complete removal of pathological vein segments
• Proven Stripper Design: Classic concept for reliable performance
Technical Specifications:
• Model: VESSEL STRIPPER Precision
• Total Length: 50.0 cm
• Olive Diameter: 2.0 mm
• Construction: Flexible/rigid shaft depending on version
• Olive: Rounded, atraumatic, fixed or rotating
• Material: Stainless Steel 1.4301
• Shape: Straight, with removable/fixed olive
• Surface: High-gloss polished for optimal gliding properties
• Special Feature: Extra long construction for deep vein segments
• Risk Class: I according to Regulation (EU) 2017/745 MDR
Areas of Application:
• Minimally invasive varicose vein surgery
• Stripping of saphena magna and parva veins
• Removal of pathological vein segments
• Ambulatory vein surgical procedures
• Treatment of varicose veins and venous insufficiency
• Perforating vein surgery
Special Safety Notes:
• FOR USE BY EXPERIENCED VASCULAR SURGICAL PERSONNEL ONLY
• Apply only under strict aseptic conditions
• Special caution with strongly adherent or inflamed veins
• Atraumatic handling to avoid vein rupture
• Check integrity and olive seating before use
• Controlled, graduated stripping technique required
• Special care near neural structures
• Strictly adhere to reprocessing guidelines for reuse
• Correct vein dissection before stripping procedure essential
• Ensure postoperative compression therapy
Write the first Review!