KELLY RETRACTOR 190MM X 57MM 27,0CM
For a larger view click on the thumbnail

KELLY RETRACTOR 190MM X 57MM 27,0CM

Art.Nr.: VUBU-07-31104
MPN: AK292/04
Manufacturer: NOPA - DIMEDA
64,10 €
19 % VAT incl. Tax-Info
excl. Shipping costs


Reference numbers for instruments from manufacturer for KELLY RETRACTOR 190MM X 57MM 27,0CM

  • Aesculap: BT 633
  • Martin: 15-611-02
  • Rudolf: RU4567-52
  • Dimeda: 18.385.57
  • Zepf: 18-3805-57
  • Downs: BG-445-02-H
  • Nopa: AK 292/04


KELLY RETRACTOR • 190MM X 57MM • 27.0CM • CE CLASS I • ISO 13485:2016

Ultra-Wide High-Depth Retractor for Definitive Exposure in the Largest Surgical Approaches

The KELLY RETRACTOR with the maximum standard dimensions of 190 mm width and 57 mm height is a CE Class I medical device manufactured according to ISO 13485:2016. This ultimate version combines extreme width with a high side wall and is designed for the definitive, stable, and broad retraction of the most massive soft tissue in the largest orthopedic, trauma, or reconstructive procedures. It offers both maximum width control and secure depth hold.

Product Highlights:

✔ Certified according to ISO 13485:2016
✔ CE marking Class I (Regulation (EU) 2017/745 MDR)
✔ Ultimate blade width (190 mm) for the largest possible exposure area
✔ High, stable side wall (57 mm) for secure hold on voluminous tissue
✔ Long standard length (27 cm) for excellent reach and powerful leverage
✔ Highly stable, slightly concave curved construction from extra-reinforced stainless steel
✔ Fully rounded, high-gloss polished edges for maximum atraumatic quality
✔ High-quality surgical stainless steel in a solid, load-optimized grade
✔ Very long, robust handle with secure-grip knurling for two-handed use
✔ Autoclavable and designed for use in high-performance surgery

Benefits of the Kelly Retractor (190x57 mm):

Definitive Width and Depth Control: The 190 mm wide and 57 mm high blade can securely encompass and controllably retract the largest tissue areas with voluminous depth profiles (e.g., entire gluteal musculature, thigh package).
Instrument for Maximum Procedures: The standard instrument of choice for extensive tumor resections, major joint revisions (hip, knee), and complex soft tissue reconstructions where conventional retractors reach their limits.
Maximum Efficiency and Overview: Enables exposure of a maximum surgical site with a single instrument, reducing the number of assistant hands required and optimizing the surgeon's overview.
Highest Patient Safety by Design: The perfectly rounded form protects tissue from sharp edges and point pressure even under high traction load.
Ergonomics Under Full Load: The specially reinforced handle allows for secure and fatigue-free handling even during maximum exertion.

Technical Specifications:

Model: Kelly Retractor, Ultra-Wide High-Depth Version
Overall Length: 27.0 cm
Blade Dimensions (W x H): 190 mm (Width) x 57 mm (Height/Blade depth)
Blade Shape: Ultra-wide, high-sided, slightly concave curved with strongly rounded ends
Handle Form: Very long, solid maximum handle with optimized knurling
Material: High-quality surgical stainless steel (e.g., 1.4301 / 316L in high-load quality)
Surface: High-gloss polished (mirror finish) for minimal friction
Special Feature: Largest available standard size for ultimate width and depth effect
Risk Class: I according to Regulation (EU) 2017/745 MDR

Areas of Application:

• Maximum exposure in extensive orthopedic tumor approaches (pelvis, femur)
• Complex revision arthroplasty of the hip and knee with extensive access
• Major reconstructive procedures in plastic and soft tissue tumor surgery
• Trauma surgical approaches for complex pelvic and acetabular fractures

Important Safety and Handling Instructions:

FOR USE BY SPECIALIZED AND HIGHLY EXPERIENCED SURGICAL PERSONNEL ONLY.
• Use under strict aseptic conditions only.
• An intensive visual inspection for material fatigue or bends is MANDATORY BEFORE EACH USE.
• The extreme blade area combined with the height creates immense leverage. Utmost dosage, control, and a tactile approach are essential to avoid tissue damage or nerve compression.
• Exercise special caution during placement to avoid compressing large neurovascular bundles.
• Reprocessing requires suitable large brushes for thorough cleaning of the very large inner surfaces.


Customer reviews:

Write the first Review!



499 Articel In this category