Precision Wound Hook according to GRAEFE with Blunt Point for Ophthalmic and Fine Surgical Applications
The GRAEFE FINE WOUND HOOK 16.0 cm is a medical device of CE Class I according to ISO 13485:2016. This precision wound hook following the proven GRAEFE design with blunt point is specifically designed for the atraumatic holding and retraction of delicate tissue in ophthalmic surgery, plastic surgery and fine dermatological procedures.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE marking Class I (Regulation (EU) 2017/745 MDR)
✔ Proven GRAEFE design with blunt point for maximum atraumatic properties
✔ High-quality stainless steel for optimal fineness and durability
✔ Tested biocompatibility according to ISO 10993
✔ Blunt hook point for gentle tissue handling
✔ Optimal length of 16.0 cm for precise surgical applications
✔ Sterilizable and reusable
Advantages of the Wound Hook:
• Blunt Precision Point: Atraumatic grasping and holding of delicate tissue structures
• Ophthalmic Design: Specifically for eyelid surgery and ophthalmic procedures
• Maximum Atraumatic Properties: Ideal for delicate tissues and repeated manipulation
• Ergonomic Handle: Secure handling even during high-precision work
• Proven Concept: GRAEFE design for highest tissue protection requirements
• Versatile Application: For ophthalmology, plastic surgery and dermatology
Technical Specifications:
• Model: GRAEFE FINE WOUND HOOK blunt
• Total Length: 16.0 cm
• Material: High-quality stainless steel 1.4301
• Hook Shape: Extremely fine, curved, with blunt point
• Handle: Finely serrated for tactile precision
• Hook Width: 2 mm (extremely fine)
• Point: Blunt and rounded for maximum tissue protection
• Surface: High-gloss polished for optimal gliding properties
• Special Feature: Specifically for ophthalmic surgical precision work with delicate structures
• Risk Class: I according to Regulation (EU) 2017/745 MDR
Areas of Application:
• Ophthalmic surgery
• Eyelid surgery (Blepharoplasty)
• Plastic facial surgery
• Fine dermatological procedures
• Microsurgical applications
• Lacrimal duct surgery
• Aesthetic surgery in facial area
• Pediatric surgical procedures
Special Safety Notes:
• FOR USE BY SURGICAL PROFESSIONALS WITH MICROSURGICAL EXPERIENCE ONLY
• Atraumatic handling of delicate tissue structures
• Check integrity and surface smoothness before each use
• Apply only under sterile conditions and with sufficient magnification
• Special care near ocular structures and neural supply areas
• Gentle application with minimal pressure required
• Strictly adhere to reprocessing guidelines for reuse
• Regular checking of hook point for smoothness and shape
• Special storage to protect the delicate point
• Particularly suitable for fragile and delicate tissue structures
Write the first Review!