Professional Retractor for Deep and Atraumatic Tissue Retraction in Visceral and Pelvic Surgery
The DEAVER RETRACTOR 38 mm / 30.5 cm is a Class I medical device manufactured according to ISO 13485:2016. This classic retractor with its broad, rounded blade is designed for controlled and atraumatic retraction of deep tissue structures in abdominal and pelvic surgery.
Product Highlights:
✔ Manufactured in accordance with ISO 13485:2016
✔ CE Marked – Class I (Regulation (EU) 2017/745 – MDR)
✔ Classic Deaver shape with wide, slightly curved blade (38 mm)
✔ Optimal length (30.5 cm) for access to deep anatomical cavities
✔ High-quality Surgical Stainless Steel 1.4301 – rust-proof, corrosion-resistant and durable
✔ Atraumatic, blunt blade edges for maximum tissue protection
✔ Robust, closed finger ring for secure and fatigue-free grip
✔ Satin (matte) finish to reduce light glare
✔ Sterilizable and reusable
Benefits of the Deaver Retractor:
• Optimal Deep Retraction: Specific blade shape enables effective holding and sparing of deep tissue.
• Atraumatic Design: Wide, rounded tip and blunt edges minimize the risk of iatrogenic tissue injury.
• Ergonomic Comfort: Balanced weight and secure grip reduce hand fatigue during long procedures.
• Excellent Visualization: Creates and maintains a clear, deep surgical field for precise work.
• Proven Reliability: A standard instrument with an established shape for demanding visceral and gynecological procedures.
Technical Specifications:
• Type: Deaver Retractor
• Blade Width: 38 mm
• Overall Length: 30.5 cm
• Blade Shape: Wide, slightly curved, blunt
• Material: Surgical Stainless Steel 1.4301 (AISI 304)
• Surface Finish: Satin (matte)
• Handle: Closed, oval ring
• Sterilization: Autoclavable up to 138°C (Steam Sterilization)
• Packaging: Individually packed in sterilizable peel pouch
• Risk Class: I according to Regulation (EU) 2017/745 (MDR)
Areas of Application:
• General and Visceral Surgery (e.g., liver, gallbladder, intestinal procedures)
• Gynecological Surgery (e.g., hysterectomies, oophorectomies)
• Urological procedures in the pelvic region
• Other surgical procedures requiring deep and atraumatic tissue retraction
Important Safety Information:
• FOR USE BY QUALIFIED MEDICAL PROFESSIONALS ONLY.
• Inspect for damage, wear, or corrosion before each use.
• Use instrument only for its intended purpose.
• Strictly adhere to recommended reprocessing and sterilization protocols for reuse.
• Tissue damage may occur if used improperly.
• Dispose of in accordance with local regulations for medical devices.