Extreme Vessel Stripper for Maximum Vein Surgery
The VESSEL STRIPPER 7.0 mm / 50.0 cm is a medical device of CE Class I according to ISO 13485:2016. This extreme stripper with its maximum 7.0 mm olive and extra-long construction is specifically designed for the atraumatic removal of extremely dilated vein segments in highly complex vascular surgery.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE marking Class I (Regulation (EU) 2017/745 MDR)
✔ Extra long 50.0 cm construction for deepest access
✔ Extreme design with maximum 7.0 mm atraumatic olive
✔ High-quality stainless steel 1.4301 – rust-free and biocompatible
✔ Tested biocompatibility according to ISO 10993
✔ Atraumatic maximum olive for safe tissue handling
✔ Maximum 50.0 cm length for most complex surgical access
✔ Sterilizable and reusable
Advantages of the Vessel Stripper:
• Extreme Tip: 7.0 mm design for maximum venous access
• Extra Length: 50.0 cm for deepest vein segments and complex anatomies
• Atraumatic Maximum Olive: Gentle preparation of extremely dilated veins
• Ultra-Stable Handling: Robust balance for controlled stripping movements
• Complete Vein Removal: Ensures complete removal of pathological maximum veins
• Special Stripper Design: For most demanding vein surgery
Technical Specifications:
• Model: VESSEL STRIPPER Extreme
• Total Length: 50.0 cm
• Olive Diameter: 7.0 mm
• Construction: Reinforced shaft for maximum stability
• Olive: Rounded, atraumatic, fixed or rotating
• Material: Stainless Steel 1.4301
• Shape: Straight, with removable/fixed maximum olive
• Surface: High-gloss polished for optimal gliding properties
• Special Feature: Extra long reinforced construction for deepest vein segments
• Risk Class: I according to Regulation (EU) 2017/745 MDR
Areas of Application:
• Extreme varicose vein surgery in maximum veins
• Stripping of extremely dilated saphena magna veins
• Removal of pathological vein segments in maximum varicosis
• Complex inpatient vein surgical procedures
• Treatment of most massive varicose veins and venous insufficiency
• Revision procedures in previously operated maximum veins
Special Safety Notes:
• FOR USE BY HIGHLY EXPERIENCED VASCULAR SURGICAL PERSONNEL ONLY
• Apply only under strict aseptic conditions
• Extreme caution with strongly adherent or inflamed maximum veins
• Atraumatic handling to avoid massive vein rupture
• Check integrity and olive seating before use
• Controlled, graduated stripping technique absolutely required
• Special care near neural structures and deep vessels
• Strictly adhere to reprocessing guidelines for reuse
• Correct vein dissection before stripping procedure essential
• Ensure intensive postoperative compression therapy
Write the first Review!