SIMPSON Obstetrical Forceps 30cm
For a larger view click on the thumbnail

SIMPSON Obstetrical Forceps 30cm

Art.Nr.: VUBU-72-10230
MPN: 72.102.30
Manufacturer: NOPA - DIMEDA
111,48 €
19 % VAT incl. Tax-Info
excl. Shipping costs


Reference numbers for instruments from manufacturer for SIMPSON Obstetrical Forceps 30cm

DIMEDA: 72.102.30



SIMPSON OBSTETRIC FORCEPS • 30 CM • CE CLASS I • ISO 13485:2016

Classical Obstetric Forceps for Compression-Free Extraction with Higher Fetal Head Station

The SIMPSON Obstetric Forceps 30 cm is a medical device of CE class I according to ISO 13485:2016. This extended classical obstetric forceps with fenestrated blades and complete pelvic curvature is specifically designed for compression-free extraction with higher fetal head station in mid-cavity.

Product Highlights:

✔ Certified according to ISO 13485:2016
✔ CE marking Class I (Directive 93/42/EEC)
✔ Extended obstetric forceps with complete pelvic curvature
✔ Fenestrated blades for reduced fetal head compression
✔ High-quality stainless steel 1.4021 – rust-free and biocompatible
✔ Tested biocompatibility according to ISO 10993
✔ Complete pelvic curvature for optimal anatomical adaptation
✔ Ergonomic ring handles with safety lock
✔ Sterilizable and reusable

Advantages of the Extended Forceps:

Extended Applicability: 30 cm length for higher head positions in mid-cavity
Reduced Head Compression: Fenestrated blades minimize pressure on the fetal head
Optimal Anatomical Adaptation: Complete pelvic curvature ideally adapts to the birth canal
Safe Application: Specifically designed for molded heads with caput succedaneum
Proven Design: Classic Simpson pattern with extended reach

Technical Specifications:

• Model: SIMPSON Obstetric Forceps
• Total Length: 30 cm
• Blades: Fenestrated, with complete pelvic curvature
• Material: Surgical Steel 1.4021
• Curvature: Complete pelvic curvature
• Handle Design: Ergonomic ring handles with safety lock
• Risk Class: I according to Directive 93/42/EEC

Fields of Application:

• Head extraction with higher fetal head station in mid-cavity
• Vacuum extraction with molded fetal head and caput succedaneum
• Prolonged second stage of labor with medium head station
• Secondary uterine inertia with higher head position
• Arrested labor in mid-cavity transverse position

Special Safety Notes:
• STRICTLY for obstetric specialists only
• Apply only with fully dilated cervix and confirmed fetal position
• Special caution required during mid-cavity application
• Correct positioning mandatory before traction
• Check for damage after use


Customer reviews:

Write the first Review!



3533 Articel In this category