Special Wound and Tracheal Hook with Tight Curve and Semi-Sharp Prong for Gentle ENT Surgical Applications
The WOUND AND TRACHEAL HOOK 16.0 cm is a medical device of CE Class I according to ISO 13485:2016. This special hook with tight curve and one semi-sharp prong is specifically designed for the gentle holding and retraction of delicate tissue in ENT surgery, tracheal surgery and endoscopic procedures.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE marking Class I (Regulation (EU) 2017/745 MDR)
✔ Special design with tight curve for limited access
✔ High-quality stainless steel for optimal precision and durability
✔ Tested biocompatibility according to ISO 10993
✔ Semi-sharp single prong for gentle but secure tissue grasping
✔ Optimal length of 16.0 cm for sensitive ENT surgical applications
✔ Sterilizable and reusable
Advantages of the Special Hook:
• Tight Curve: Ideal for limited access in trachea and upper airways
• Semi-Sharp Prong: Gentle grasping with reduced trauma risk
• ENT-specific Design: Specifically for sensitive laryngological and tracheal procedures
• Optimal Visibility: Provides good view with gentle retraction
• Atraumatic Application: Ideal for mucous membranes and delicate tissues
• Precise Guidance: Exact control during endoscopic procedures
Technical Specifications:
• Model: WOUND AND TRACHEAL HOOK
• Total Length: 16.0 cm
• Material: High-quality stainless steel 1.4301
• Hook Shape: Tight curve, one semi-sharp prong
• Handle: Longitudinal serrations for secure, measured grip
• Number of Prongs: 1
• Prong Shape: Semi-sharp, rounded tip with controlled grip
• Curve Radius: Tight for limited anatomical access
• Surface: High-gloss polished for optimal gliding properties
• Special Feature: Specifically for atraumatic tracheal and laryngological surgery
• Risk Class: I according to Regulation (EU) 2017/745 MDR
Areas of Application:
• Sensitive ENT surgical procedures
• Tracheal surgery with delicate mucous membranes
• Laryngoscopic procedures requiring atraumatic technique
• Endoscopic operations on sensitive structures
• Wound retraction in limited access with fragile tissues
• Laryngeal surgery with mucosal preservation
• Pediatric ENT surgery
Special Safety Notes:
• FOR USE BY ENT SURGICAL PROFESSIONALS ONLY
• Particularly gentle handling despite semi-sharp prong
• Check integrity and surface condition before each use
• Apply only under sterile conditions
• Special care near tracheal and laryngeal mucous membranes
• Measured, controlled application required
• Strictly adhere to reprocessing guidelines for reuse
• Regular checking of prong for shape and smoothness
• Special storage to protect the tip
• Do not use for resistant or fibrous tissue