Ultra-maximum dilator with French scaling for extreme surgical access
The PRATT Uterus Dilator double S-shaped 17.6 mm / 18.3 mm is a CE Class I medical device according to ISO 13485:2016. This ultra-maximum dilator with French scale (Charrière 53/55) enables extreme cervical expansion for highly specialized maximum operative gynecological procedures.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE Mark Class I (Directive 93/42/EEC)
✔ Ultra-maximum dilator 17.6 mm / 18.3 mm with French scale
✔ International size designation: Charr. 53/55
✔ Double S-shaped anatomy for optimal guidance
✔ High-quality stainless steel 1.4301 - rust-free and biocompatible
✔ Tested biocompatibility according to ISO 10993
✔ Ultra-attraumatic special tips
✔ Extremely reinforced ergonomic safety ring handles
✔ Sterilizable and reusable
Advantages of the PRATT Ultra-Maximum Dilator:
• International compatibility: French scale (Charrière) for European application
• Ultimate progression: Optimal gradation from 17.6 mm to 18.3 mm
• Extreme dilation: For highly specialized maximum procedures with extreme instruments
• Ultra stability: High-strength construction for extreme mechanical loads
• Clear identification: Internationally standardized size marking
Technical Specifications:
• Model: PRATT Dilator double S-shaped
• Sizes: 17.6 mm / 18.3 mm (double-ended)
• French scale: Charrière 53/55
• Curvature: Double S-shaped, anatomically optimized
• Material: Surgical Steel 1.4301
• Tip form: Ultra-attraumatic, extremely stable
• Handle design: Ergonomic with safety rings, maximum control
• Risk Class: I according to Directive 93/42/EEC
International Size Correspondence:
• 17.6 mm corresponds to French Scale Charr. 53
• 18.3 mm corresponds to French Scale Charr. 55
Areas of Application:
• Internationally standardized extreme surgical access
• Ultimate cervical dilation for special maximum procedures
• Preparation for ultra-large resectoscopes and special instruments
• Highly complex oncological ultra-maximum procedures
• Exceptional intrauterine surgical procedures
Important Safety Information:
• FOR HIGHEST SPECIALIZED GYNECOLOGICAL PROFESSIONALS ONLY
• Use only after complete gradual preliminary dilation up to 16.9 mm
• Utmost caution and ultra-gentle dilation technique required
• Maximum anesthesia depth and muscle relaxation absolutely necessary
• Correctly interpret French scale designation
• Strictest reprocessing and sterilization protocols required
Write the first Review!