Robust surgical retractor for stable tissue retraction in orthopaedic and trauma surgery
The MEYERDING Retractor FIG-1 with working dimensions of 18mm wide x 7mm deep is a Class I medical device manufactured according to ISO 13485:2016. This sturdy, single-ended hook following the design of Dr. Henry W. Meyerding is specifically engineered for stable retraction of soft tissue and muscle during deep orthopaedic and trauma procedures.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE marking Class I (Regulation (EU) 2017/745 - MDR)
✔ Robust FIG-1 (Figure-1) shape for stable leverage and deep access
✔ Optimal working width of 18mm for efficient soft tissue retraction
➤ Exclusively designed for deep orthopaedic approaches
✔ Precision-forged from high-grade stainless steel 1.4301/316L
✔ Satin finish for glare-free visibility in the surgical field
✔ Ergonomic, sturdy handle for fatigue-free application
✔ Autoclavable and reusable
Benefits of the MEYERDING Retractor:
• Deep Retraction: With 7mm depth, ideal for exposing bony structures in spinal, hip, or pelvic procedures
• Stable Exposure: The broad 18mm blade ensures secure, stable holding function without tissue cut-through
• Optimised Leverage: The classic FIG-1 design efficiently transfers hand force for effortless retraction
• Reduced Fatigue: Enables longer holding times without comfort loss due to stable design
• Proven Design: Established instrument design for standardised orthopaedic approaches
Technical Specifications:
• Model: MEYERDING Retractor, Type FIG-1
• Working Dimensions: Width 18mm × Depth 7mm
• Design: Single-ended hook, classic "Figure-1" shape
• Material: Surgical Stainless Steel 1.4301 / 316L
• Surface: Matte/Satin (non-reflective)
• Sterilisation: Autoclavable up to 138°C (steam sterilisation)
• Risk Class: I according to Regulation (EU) 2017/745 (MDR)
Fields of Application:
• Spinal Surgery: Retraction in dorsal lumbar and thoracic approaches
• Hip Arthroplasty: Soft tissue retraction in posterior and lateral approaches
• Trauma Surgery: Exposure of fractures during open reconstructions
• General Orthopaedics: Deep approaches to large joints (shoulder, knee)
• Pelvic Surgery: Retraction in approaches to the acetabulum or iliac crest
Important Safety Instructions:
• FOR USE BY SURGICAL PROFESSIONALS ONLY
• Not suitable for superficial or microvascular procedures
• Inspect for structural integrity before use (no cracks or deformations)
➤ Apply under direct visual control to avoid nerve or vascular injury
• For reuse, strictly adhere to current reprocessing guidelines
Write the first Review!