Professional Fistula Probe for Complex Proctological Explorations
The LOCKHART-MUMMERY PROBE FIG-1 19.0 cm is a medical device of CE Class I according to ISO 13485:2016. This special fistula probe with its characteristic curved tip was developed by the famous surgeon Sir John Lockhart-Mummery for precise exploration of complex fistula tracts, abscess cavities and sinus tracts in the anorectal region.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE Marking Class I (Regulation (EU) 2017/745 MDR)
✔ Original Lockhart-Mummery design with curved tip
✔ Special FIG-1 version for anorectal explorations
✔ High-quality Stainless Steel 1.4301 – rust-free and biocompatible
✔ Tested Biocompatibility according to ISO 10993
✔ Rounded, slightly curved tip for maximum patient safety
✔ Optimal 19.0 cm length for deep proctological explorations
✔ Sterilizable and reusable
✔ Precision instrument for complex fistula surgery
Benefits of the Lockhart-Mummery Probe:
• Special Curvature: Anatomically shaped tip for optimal accessibility of anorectal fistulas
• Precise Tactile Feedback: Optimally transmits tissue consistency and fistula courses
• Atraumatic Exploration: Rounded tip minimizes tissue damage
• Proven Effectiveness: Time-tested design used for generations in proctology
• Optimal Length: 19.0 cm provides sufficient reach for proctological procedures
Technical Specifications:
• Model: LOCKHART-MUMMERY PROBE FIG-1
• Total Length: 19.0 cm
• Construction: Stable probe with characteristic curvature
• Tip: Rounded, closed, slightly curved (FIG-1)
• Material: Stainless Steel 1.4301
• Form: Straight shaft with curved tip
• Diameter: Standard size for proctological applications
• Surface: High-gloss polished for optimal gliding properties
• Special Feature: Original Lockhart-Mummery design
• Risk Class: I according to Regulation (EU) 2017/745 MDR
Fields of Application:
• Exploration of anorectal fistula tracts
• Probing of perianal abscess cavities
• Proctological diagnostics
• Examination of sinus tracts
• Fistula surgery procedures
• Rectal explorations
• Diagnostics for Crohn's disease and ulcerative colitis
Important Safety Information:
• FOR USE BY PROCTOLOGICAL PROFESSIONALS ONLY
• Apply only under strict aseptic conditions
• Check for damage and surface integrity before use
• Handle atraumatically to avoid tissue damage
• Use controlled, slow probing technique
• Special caution in inflamed or fragile tissue structures
• Stop probing immediately if resistance is encountered
• Use sufficient lubricant
• Not suitable for excessive force application
• Strictly follow reprocessing guidelines for reuse
Write the first Review!