SIMPSON OBSTETRIC FORCEPS • 23 CM • CE CLASS I • ISO 13485:2016

Classical Obstetric Forceps for Compression-Free Head Extraction with Molded Fetal Head

The SIMPSON Obstetric Forceps 23 cm is a medical device of CE class I according to ISO 13485:2016. This classical obstetric forceps with fenestrated blades and complete pelvic curvature is specifically designed for compression-free extraction of the molded fetal head.

Product Highlights:

✔ Certified according to ISO 13485:2016
✔ CE marking Class I (Directive 93/42/EEC)
✔ Classical obstetric forceps with complete pelvic curvature
✔ Fenestrated blades for reduced compression
✔ High-quality stainless steel 1.4021 – rust-free and biocompatible
✔ Tested biocompatibility according to ISO 10993
✔ Complete pelvic curvature for anatomical adaptation
✔ Ergonomic ring handles with safety lock
✔ Sterilizable and reusable

Advantages of the Classical Forceps:

Reduced Head Compression: Fenestrated blades minimize pressure on the fetal head
Optimal Anatomical Adaptation: Complete pelvic curvature ideally adapts to the birth canal
Safe Application: Specifically designed for molded heads with caput succedaneum
Precise Control: Ergonomic handles enable controlled traction maneuvers
Proven Design: Classic Simpson pattern used for generations

Technical Specifications:

• Model: SIMPSON Obstetric Forceps
• Total Length: 23 cm
• Blades: Fenestrated, with complete pelvic curvature
• Material: Surgical Steel 1.4021
• Curvature: Complete pelvic curvature
• Handle Design: Ergonomic ring handles with safety lock
• Risk Class: I according to Directive 93/42/EEC

Fields of Application:

• Head extraction with molded fetal head and caput succedaneum
• Vacuum extraction in mid-cavity and outlet
• Prolonged second stage of labor with maternal exhaustion
• Secondary uterine inertia in late labor phase
• Arrested labor in deep transverse position

Special Safety Notes:
• STRICTLY for obstetric specialists only
• Apply only with fully dilated cervix and confirmed fetal position
• Contraindicated with non-engaged fetal head
• Ensure correct positioning before application
• Check for damage after use