Flexible Maximum Vessel Dilator for Deepest Major Vessel Procedures
The GARRETT VESSEL DILATOR FLEXIBLE 5.0MM 21.0 cm is a medical device of CE Class I according to ISO 13485:2016. This flexible maximum vessel dilator with maximum length was specifically developed for the gentle dilation of largest main vessels in deepest vascular surgery, cardiac surgery and transplantation surgery maximum procedures.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE Marking Class I (Regulation (EU) 2017/745 MDR)
✔ Garrett Vessel Dilator with 5.0 mm maximum diameter
✔ Flexible version for deepest anatomical adaptation
✔ High-quality Stainless Steel 1.4301 – rust-free and biocompatible
✔ Tested Biocompatibility according to ISO 10993
✔ Maximum size 5.0 mm tip for largest main vessels
✔ Maximum 21.0 cm length for deepest maximum procedures
✔ Sterilizable and reusable
✔ Maximum special instrument for most demanding deep main vessel reconstructions
Benefits of the Garrett Vessel Dilator:
• Maximum Flexibility in Depth: Bendable 5.0 mm version for largest vessel dilation in deepest body regions
• For Deepest Maximum Vessels: Ideal for abdominal aorta, vena cava and main iliac trunks with maximum diameter
• Atraumatic Maximum Tip: High-gloss polished surface minimizes vessel injuries in maximum caliber
• Precise Maximum Deep Handling: Maximum length for safe control in largest main vessels in depth
• Ultimate Maximum Design: Highest quality instrument for most demanding deep maximum vessel procedures
Technical Specifications:
• Model: GARRETT VESSEL DILATOR FLEXIBLE
• Total Length: 21.0 cm
• Diameter: 5.0 mm
• Construction: Flexible maximum vessel dilator with deep reach
• Tip: Rounded, atraumatic
• Material: Stainless Steel 1.4301
• Form: Straight, flexible shaft
• Surface: High-gloss polished for optimal gliding properties
• Flexibility: Minimal bend for stable maximum vessel dilation in depth
• Risk Class: I according to Regulation (EU) 2017/745 MDR
Fields of Application:
• Deepest maximum vessel surgery (abdominal aorta, vena cava)
• Deep iliac maximum vessel procedures
• Cardiac surgical deep maximum reconstructions
• Transplantation surgery with maximum vessels and ultra reach
• Trauma deep maximum vessel repairs
• Most complex deep bypass surgery with main vessels
• Arterial deep maximum reconstructions in end-stage PAD
Important Safety Information:
• FOR USE BY MAXIMUM-SPECIALIZED VASCULAR SURGICAL PROFESSIONALS ONLY
• Apply only under strict aseptic conditions in maximum care centers
• Check for damage and surface integrity before use
• Exercise extreme caution during dilation of largest main vessels with severe pathological alterations in depth
• Not suitable for excessive force application
• Use maximum-controlled deep dilation technique
• Stop dilation immediately if resistance, most massive calcifications or unstable plaques are encountered
• Exercise maximum care near deep aneurysmal, dissected or rupture-prone maximum vascular structures
• Intensive regular inspection of shaft stability and tip integrity with ultra reach required
• Exercise utmost concentration and attention with maximum reach applications
• Special caution in patients with most severe end-stage vascular disease
• Use only after comprehensive imaging diagnostics
• Strictly follow reprocessing guidelines for reuse
Write the first Review!