Flexible Vessel Dilator for Deep Microvascular Surgery
The GARRETT VESSEL DILATOR FLEXIBLE 1.5MM 21.0 cm is a medical device of CE Class I according to ISO 13485:2016. This flexible vessel dilator with extended length was specifically developed for the gentle dilation of small to medium vessels in deep microsurgical, plastic surgical and vascular surgical procedures.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE Marking Class I (Regulation (EU) 2017/745 MDR)
✔ Garrett Vessel Dilator with 1.5 mm diameter
✔ Flexible version for deep anatomical adaptation
✔ High-quality Stainless Steel 1.4301 – rust-free and biocompatible
✔ Tested Biocompatibility according to ISO 10993
✔ Precise 1.5 mm tip for small to medium vessels
✔ Extended 21.0 cm length for deep vascular surgical procedures
✔ Sterilizable and reusable
✔ Special instrument for demanding deep vascular reconstructions
Benefits of the Garrett Vessel Dilator:
• Flexible Deep Construction: Bendable version for gentle vessel dilation in depth
• Ideal Size for Depth: 1.5 mm perfect for small to medium vessels in deep anastomoses
• Atraumatic Deep Tip: Smooth polished surface minimizes vessel injuries
• Optimal Deep Reach: 21.0 cm for excellent control in deep anatomical regions
• Proven Deep Design: Tested instrument for microvascular deep procedures
Technical Specifications:
• Model: GARRETT VESSEL DILATOR FLEXIBLE
• Total Length: 21.0 cm
• Diameter: 1.5 mm
• Construction: Flexible vessel dilator with deep reach
• Tip: Rounded, atraumatic
• Material: Stainless Steel 1.4301
• Form: Straight, flexible shaft
• Surface: High-gloss polished for optimal gliding properties
• Flexibility: High for anatomical adaptation in depth
• Risk Class: I according to Regulation (EU) 2017/745 MDR
Fields of Application:
• Deep microvascular anastomoses
• Plastic surgical deep tissue transplantations
• Reconstructive vascular surgery in deep regions
• Peripheral deep vessel procedures
• Hand surgical deep vascular reconstructions
• Deep digital replantations
• Free flap transplantations with extended reach
Important Safety Information:
• FOR USE BY VASCULAR SURGICAL PROFESSIONALS ONLY
• Apply only under strict aseptic conditions
• Check for damage and surface integrity before use
• Exercise particular caution during handling due to extended length
• Not suitable for excessive force application
• Use slow, controlled dilation technique
• Stop dilation immediately if resistance is encountered
• Exercise particular care near sensitive vascular structures in depth
• Exercise increased attention with extended reach applications
• Strictly follow reprocessing guidelines for reuse
Write the first Review!