Precision Wound Hook according to FIG-4 for Maximum Surgical Applications
The FINE WOUND HOOK FIG-4 16.0 cm is a medical device of CE Class I according to ISO 13485:2016. This precision wound hook following the maximum FIG-4 design is specifically designed for the secure holding and retraction of resistant soft tissue and deep wound edges in general surgery, trauma surgery and orthopedic surgery.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE marking Class I (Regulation (EU) 2017/745 MDR)
✔ Maximum FIG-4 design for powerful retraction
✔ High-quality stainless steel for extreme stability and durability
✔ Tested biocompatibility according to ISO 10993
✔ Highly reinforced hook ends for secure tissue handling
✔ Optimal length of 16.0 cm for powerful surgical applications
✔ Sterilizable and reusable
Advantages of the Wound Hook:
• Maximum Design: Strongest hook shape for most demanding retraction tasks
• Optimal Leverage: Excellent retraction even with most resistant tissue
• Highly Stable Construction: Extremely robust design for maximum load capacity
• Professional Handle: Secure grip even during powerful maneuvers
• Proven Concept: FIG-4 design for maximum surgical requirements
• Versatile Application: Ideal for deep wound edges and resistant tissue
Technical Specifications:
• Model: FINE WOUND HOOK FIG-4
• Total Length: 16.0 cm
• Material: High-quality stainless steel 1.4301
• Hook Shape: Single hook, maximum strong and stable
• Handle: Heavily serrated for absolutely secure grip
• Hook Width: 9 mm (maximum strong)
• Hook Form: Strongly curved for optimal access to deep structures
• Surface: High-gloss polished for optimal gliding properties
• Special Feature: Maximum reinforced design for most demanding retractive tasks
• Risk Class: I according to Regulation (EU) 2017/745 MDR
Areas of Application:
• General surgery
• Trauma surgery
• Orthopedic soft tissue surgery
• Deep wound revisions and debridements
• Fascia surgery
• Reconstructive procedures
• Surgery in adipose tissue
Special Safety Notes:
• FOR USE BY EXPERIENCED SURGICAL PROFESSIONALS ONLY
• Controlled but powerful tissue handling required
• Check maximum integrity and stability before each use
• Apply only under aseptic conditions
• Measured but sufficient pressure for effective retraction
• Strictly adhere to reprocessing guidelines for reuse
• Regular checking of hook structure for strength
• Do not use for bony structures
• Special caution with fragile tissue despite strong construction
Write the first Review!