Ultra-Long Cotton Carrier for Most Extreme Depth Explorations and Special Procedures
The FEIN COTTON CARRIER 28.0 cm is a medical device of CE Class I according to ISO 13485:2016. This ultra-long cotton carrier with its extreme length was specifically developed for neurosurgical procedures, spinal explorations and applications in deepest anatomical regions that cannot be reached with standard instruments.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE Marking Class I (Regulation (EU) 2017/745 MDR)
✔ Fein Cotton Carrier with Ultra-Long design
✔ Special design for neurosurgical and spinal deep procedures
✔ High-quality Stainless Steel 1.4301 – rust-free and biocompatible
✔ Tested Biocompatibility according to ISO 10993
✔ Extreme 28.0 cm length for most inaccessible surgical fields
✔ Sterilizable and reusable
✔ Precision instrument for most demanding depth applications
Benefits of the Fein Cotton Carrier:
• Extreme Length: 28.0 cm for procedures in deepest anatomical regions
• Optimized Precision: Special design for neurosurgical and spinal applications
• Maximum Reach: Enables applications in otherwise inaccessible areas
• Atraumatic Tip: High-gloss polished surface minimizes tissue trauma
• Special Manufacturing: Designed for most extreme surgical challenges
Technical Specifications:
• Model: FEIN COTTON CARRIER
• Total Length: 28.0 cm
• Construction: Ultra-long cotton carrier for deep procedures
• Tip: Rounded, standard for cotton carrier attachments
• Material: Stainless Steel 1.4301
• Form: Straight shaft for maximum reach
• Surface: High-gloss polished for optimal gliding properties
• Special Feature: Extreme length for special procedures
• Risk Class: I according to Regulation (EU) 2017/745 MDR
Fields of Application:
• Neurosurgical deep procedures
• Spinal operations and explorations
• Thoracic surgical deep applications
• Visceral extreme procedures
• Orthopedic deep operations
• Deepest wound cleaning and revisions
• Diagnostic swabs in most inaccessible regions
Important Safety Information:
• FOR USE BY HIGHLY SPECIALIZED SURGICAL PROFESSIONALS ONLY
• Apply only under strict aseptic conditions
• Check for damage and surface integrity before use
• Exercise extreme caution during application in deep anatomical structures
• Securely and properly attach cotton swabs
• Exercise special care due to the extreme length
• Not suitable for excessive force application
• Stop application immediately if resistance is encountered
• Regular inspection of shaft stability required
• Strictly follow reprocessing guidelines for reuse
Write the first Review!