Broad Surface Retractor with Lattice Handle for Ergonomie Large-Area Retraction
The BRUNNER RETRACTOR 80mm x 20mm with flat lattice handle is a CE-Class I medical device manufactured according to ISO 13485:2016. This special version combines a wide retraction blade with a flat lattice handle and is specifically designed for procedures requiring large-area, yet even tissue retraction with maximum grip comfort.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE Marking Class I (Regulation (EU) 2017/745)
✔ Brunner retractor with characteristic flat lattice handle
✔ Wide blade (80mm x 20mm) for effective area retraction
✔ Flat lattice handle for fatigue-free, non-slip grip
✔ High-quality Stainless Steel 1.4301 – rust-proof and biocompatible
✔ Tested Biocompatibility according to ISO 10993
✔ Forged from one piece for optimal stability
✔ Length of 25.0 cm for deep surgical approaches
✔ Sterilizable and reusable
Advantages of the Brunner Retractor:
• Optimal Area Retraction: The 80 mm wide blade enables effective retraction of large tissue areas
• Ergonomic Comfort: Flat lattice handle provides excellent grip and reduces hand fatigue
• Even Pressure Distribution: Wide contact surface minimizes local tissue stress
• Secure Handling: Lattice structure prevents slipping even under wet conditions
• Versatile Application: Ideal for abdominal, orthopedic, and thoracic procedures with large-area retraction
Technical Specifications:
• Model: BRUNNER RETRACTOR with flat lattice handle
• Overall Length: 25.0 cm
• Blade Dimensions (Width x Height): 80 mm x 20 mm
• Handle Design: Flat lattice handle with ergonomic profile
• Material: Stainless Steel 1.4301 / AISI 304
• Construction: Forged from one piece, solid
• Blade Shape: Wide with slightly rounded edges
• Surface: Matte, low reflection
• Special Feature: Combination of broad surface blade and flat lattice handle for maximum ergonomics
• Risk Class: I according to Regulation (EU) 2017/745
Fields of Application:
• Abdominal Surgery: Retraction of abdominal wall during major laparotomies
• Orthopedic Surgery: During hip and knee arthroplasty with large-area exposure
• Thoracic Surgery: Retraction during thoracotomies
• Vascular Surgery: For extensive vascular exposures
• Plastic Surgery: Retraction of large skin areas during reconstructive procedures
Important Safety Notes:
• FOR USE BY MEDICAL PROFESSIONALS ONLY
• Use under aseptic conditions only
• Check for damage before each use – especially control stability of lattice handle
• Tissue-preserving application – distribute pressure evenly across entire blade surface
• Controlled retraction – consider the leverage effect
• During reprocessing thoroughly clean lattice structure and blade surface
• Correct storage – protect flat handle from deformation
• Do not use as a lever instrument – for retraction purposes only
Write the first Review!