Clinics, hospitals and surgical facilities need reliable sterilization containers that perform in daily operating-room use – without compromising standards compliance or safe handling. Our container range has been developed to meet precisely these requirements.
Our sterilization containers come from the Tuttlingen medical technology manufacturing network – one of the world's leading centres for surgical instrument production. This origin stands for precision workmanship, durable materials and high manufacturing standards on which hospitals and procurement teams rely every day.
All our surgical instruments and sterilization containers are certified to DIN EN ISO 13485:2016 and bear the CE mark. The products therefore meet the requirements of the EU Medical Device Regulation (MDR) and are suitable for regulated use in hospitals and medical practices.
Our sterilization containers comply with the relevant standards for sterile barrier packaging and are validated for use in autoclaves. Hospitals and sterile services departments can thus establish a documented and reproducible sterile supply cycle – a key quality feature in clinical and operating-room practice.
Every sterilization container is checked for workmanship, function and completeness before dispatch. This ensures that facilities receive products ready for use and suited to the demanding requirements of hygienic sterile supply.
Based on more than 220 verified customer reviews, VUBU-Medical has an overall rating of 4.79 out of 5.00. These reviews come from physicians, clinics and medical purchasing professionals who regularly use our products in practice.
We offer payment on account to doctors, clinics, hospitals and medical purchasing departments. This allows orders to be integrated easily into existing procurement processes – without advance payment or unnecessary administration.
Our container range includes 1/1, 3/4 and 1/2 sizes in different heights, together with matching wire baskets, filters, silicone mats and identification labels. Coloured lids and label holders allow clear identification of sterile goods and simplify administration in everyday operating-room use.
VUBU® container models feature extra-long handles with silicone-rubber coverings. These help protect against burns and prevent slipping when handling hot containers immediately after an autoclave cycle. The integrated spring-loaded closure allows excess pressure to escape in a controlled manner and then closes the container securely again.
“Very reasonably priced and really good. We will order more instruments here.”
“We have received 50 pieces of these evacuators. Very well packaged and of excellent quality. Thank you very much.”
Our range of autoclavable sterilization containers covers the principal sizes required in clinical sterile processing. All models are available in standard and safety versions and can be supplemented with suitable accessories.
The 1/1 standard sterilization container is the most widely used container size for surgical instrument trays. Available with a perforated or non-perforated base and a perforated lid in several heights from 100 to 260 mm.
The 1/1 safety sterilization container provides additional protection through a lockable safety lid, optionally with an external button. This version is particularly suitable for facilities with higher requirements for securing sterile goods and controlling access.
The 3/4 standard sterilization containers offer a more compact alternative to full-size containers. They are suitable for medium-sized instrument trays and easier to handle in confined sterilization areas.
The 3/4 safety sterilization container has the same safety features as the 1/1 safety container and is specifically designed for facilities that prefer the 3/4 format.
The 1/2 standard sterilization container is the smallest container class in the VUBU range. It is suitable for smaller instrument sets, specialised trays and use in outpatient surgery and dental practices.
The 1/2 safety sterilization container has the same lockable lid as the larger safety versions and provides maximum sterile-goods security in a compact format.
Our dental container and sterilization cassette range includes specially sized containers for dental and clinical practice. Available products include dental containers, optical instrument sterilization cassettes, brush containers and sterilization cassettes for smaller instrument quantities.
optical instrument sterilization cassettes are designed for delicate optical instruments and endoscopic accessories. They provide protective, standards-compliant storage for instruments requiring particular care during sterilization.
brush containers are specifically designed to hold cleaning brushes and similar accessories that require regular sterilization as part of the cleaning process.
Matching wire baskets and accessories are available separately for all container sizes. Silicone mats, filters, identification labels and reusable PTFE filters allow each container system to be configured individually.
Choosing the right sterilization container depends on where it will be used, instrument dimensions and the sterilization process.
Sterilization containers made of anodized aluminium are suitable for the safe storage and transport of surgical instruments between the sterile processing department, storage area and operating theatre. Aluminium's low weight makes everyday handling easier in clinical settings.
In hospitals and clinics, colour-coded containers allow instrument trays to be clearly assigned to departments or procedures. Identification labels and label holders support complete documentation of the sterile supply cycle.
dental containers and sterilization cassettes provide dental practices with a standards-compliant solution for regular sterilization of handpieces, contra-angle handpieces, drills and other dental instruments.
Optical instrument sterilization cassettes secure delicate optics and endoscopic instruments during the autoclave cycle. They prevent mechanical damage while ensuring complete steam penetration.
Brush containers allow cleaning brushes used in instrument reprocessing to be sterilized in an autoclave. They complete the processing cycle and ensure that cleaning accessories themselves can be stored free of microorganisms.
For implant containers and special formats, we offer silicone mats by the metre in three colours (green, transparent and brown). They can be cut to the required internal dimensions and protect delicate implants or instruments from damage caused by movement inside the container.
All VUBU® sterilization containers are made of anodized aluminium. The material is corrosion-resistant and lightweight, and allows rapid, even drying after a steam sterilization cycle. This is particularly important for sterile-goods safety, as residual moisture can compromise sterility.
Container bases and lids are available in perforated and non-perforated versions. Perforated bases improve steam penetration and drying during autoclaving. Non-perforated bases are suitable for applications where direct steam contact from below is not desired.
The integrated spring-loaded closure safely releases excess pressure during the autoclave cycle and automatically closes the lid after pressure equalization. This function protects container integrity and supports safe sterilization without manual intervention.
The filter holder is inserted simply by pressing the centre of the filter and released by pressing the tab. This system allows quick, tool-free filter changes during routine operation and reduces container maintenance effort.
As an alternative to filter-based containers, we offer models with a valve system. The valve opens in response to pressure changes in the autoclave, allowing steam to enter and escape in a controlled manner. Once the pressure has equalized, the spring mechanism closes the valve plates completely again – keeping the container sealed and sterile.
Coloured lids allow instrument containers to be assigned to specific departments or procedures. Label holders accommodate identification labels and support transparent, traceable sterile-goods management – an essential requirement for quality assurance in operating-room practice.
The extra-long handles of VUBU® container models are covered with silicone rubber. This covering protects staff when handling hot containers immediately after sterilization and provides a secure grip even in damp conditions.
Each container size is available in several heights. The 1/1 containers are offered in heights of 100, 135, 150 and 200 mm, up to 260 mm. This allows the container height to be matched to the quantity and dimensions of instruments in each surgical tray.
Reusable sterilization containers made of anodized aluminium are designed for long-term use in clinical sterile processing. Correct reprocessing between sterilization cycles is essential for product service life and continued compliance with applicable standards.
Before sterilization, instruments must be cleaned and disinfected according to the facility's cleaning protocol. The instruments are arranged in a suitable wire basket and placed inside the container. Avoid overfilling the basket to ensure even steam penetration.
Filter containers or valve containers are generally used for steam sterilization in an autoclave at 134 °C. The choice of suitable filter type or valve system depends on the equipment manufacturer's instructions and the facility's internal reprocessing protocols.
Autoclavable sterilization containers made of anodized aluminium are suitable for steam sterilization using common 121 °C and 134 °C programmes. During the cycle, the filter or valve system enables complete steam penetration and controlled pressure equalization.
After the sterilization cycle, containers must first be allowed to cool under controlled conditions. Perforated bases and lids promote complete drying of sterile goods – an important step in avoiding residual moisture that could compromise sterility.
Sterilized containers are stored under sterile storage conditions until required. VUBU® container label holders support correct identification with the sterilization date, expiry date and batch assignment.
Sterilized containers should be transported with minimal risk of contamination. Closed containers protect sterile goods until opened in the operating theatre. The spring-loaded closure ensures that the lid cannot be opened unintentionally during transport.
Between sterilization cycles, containers must be checked for damage to seals, filters, valves and closures. Defective filters must be replaced. Seals and valve plates should be checked regularly for proper operation. Containers are cleaned in accordance with internal reprocessing protocols.
A fully traceable sterile supply cycle requires consistent labelling of every container. VUBU® label holders accommodate standard identification labels, allowing contents, sterilization date and intended use to be clearly assigned – a fundamental requirement for quality assurance in hospital sterile processing.