Mega Curette Blunt & Flexible for Ultimate Safety in Maximum Curettages
The BUMM Uterine Curette (Fig. 15, 35mm, 34cm) blunt and flexible is a medical device of CE Class I according to ISO 13485:2016. This mega version offers ultimate curette size with safe blunt flexibility for tissue-sparing maximum curettages in extremely extensive findings.
Product Highlights:
✔ Certified according to ISO 13485:2016
✔ CE marking Class I (Directive 93/42/EEC)
✔ Mega size 35mm (Fig. 15) – for ultimate efficiency in maximum curettages
✔ Optimal working length 34cm – for complex anatomical access
✔ High-quality stainless steel 1.4301 – rust-free, biocompatible and autoclavable
✔ Tested biocompatibility according to ISO 10993 – guaranteed tissue compatibility
✔ Mega-precision blunt edge – ultimate safety against uterine perforation
✔ Highly flexible special construction – for optimal adaptation to uterine contours
✔ Medical premium manufacturing – for extreme safety procedures
✔ Sterile packaged – individually and ready for immediate use
✔ Multi-use – provided strict reprocessing protocols are consistently followed
Benefits of the BUMM Uterine Curette Blunt & Flexible Fig. 15 34cm:
• Mega size 35mm for ultimate efficiency in maximum findings
• Blunt, tissue-sparing edge eliminates the risk of iatrogenic injury
• Highly flexible design enables gentle adaptation to uterine anatomy
• Optimal length for procedures with complex anatomical conditions
Areas of Application:
• Therapeutic curettage for extremely extensive, benign uterine findings
• Ultimate gentle removal of largest placental remnants in risk patients
• Management of incomplete abortion with maximum tissue volumes
• Controlled curettage in patients with absolute perforation risk
Technical Specifications:
• Model: BUMM Uterine Curette
• Type: Blunt and flexible, Figure 15
• Curette size: 35 mm
• Total length: 34 cm
• Material: Surgical Steel 1.4301
• Type: Reusable
• Flexibility: Highly flexible
• Mechanism: Manual
• Risk Class: I according to Directive 93/42/EEC
• Sterilization: Suitable for steam sterilization (autoclave)
Important Safety Information:
• EXCLUSIVELY for highly experienced specialist physicians in gynecological surgery
• Application requires a stable cervix and a sufficiently dilated cervical canal
• Procedures ONLY for compelling indications and after ultimate benefit-risk assessment
• Perform a VISUAL and FUNCTIONAL CHECK for damage before each use
• During reprocessing, the requirements of the German Medical Device Operator Ordinance (MPBetreibV) MUST be STRICTLY OBSERVED.